{"product_id":"allen-bradley-193-dnct-devicenet-configuration-terminal","title":"Allen-Bradley 193-DNCT DeviceNet Configuration Terminal","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandheld configuration terminal from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eRockwell Automation\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley is designed for commissioning, diagnostics, and parameter management on DeviceNet communication networks. Developed primarily for Bulletin 193 electronic overload relays and ArmorStart distributed motor controllers, the terminal enables direct field-level access to DeviceNet nodes without requiring PC-based configuration software.\u003c\/p\u003e\n\u003cp\u003eIts portable design and menu-driven interface allow maintenance personnel and commissioning engineers to quickly configure network devices, verify communication status, monitor I\/O activity, and troubleshoot DeviceNet installations directly from the control panel or field cabinet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePortable DeviceNet network configuration terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic network baud rate recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic DeviceNet node addressing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMenu-driven parameter configuration interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeviceNet network scan and node discovery function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time I\/O monitoring capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork diagnostic and statistics monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect parameter read\/write functionality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with multiple Allen-Bradley DeviceNet products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes DeviceNet communication cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Configuration Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Compliance\u003c\/td\u003e\n\u003ctd\u003eODVA DeviceNet Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Method\u003c\/td\u003e\n\u003ctd\u003eHandheld Menu-Driven Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Baud Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Address Assignment\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter Editing\u003c\/td\u003e\n\u003ctd\u003eRead\/Write Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Scan Function\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Monitoring\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Statistics Monitoring\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Interface\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Communication Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Cable\u003c\/td\u003e\n\u003ctd\u003e193-CB1 1-Meter DeviceNet Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e193-CM1 Cable, 193-DNCT-BZ1 Bezel Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Devices\u003c\/td\u003e\n\u003ctd\u003eBulletin 193-EC, 592-EC, ArmorStart Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standards\u003c\/td\u003e\n\u003ctd\u003eEN61000-6-4:2001, EN61000-6-2:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eCE Marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eEnd of Life Scheduled Dec 1, 2027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSupported Device Families\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal is compatible with several Allen-Bradley DeviceNet-enabled motor control and overload protection products, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBulletin 193-EC electronic overload relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBulletin 592-EC overload relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmorStart distributed motor controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeviceNet-enabled motor starter systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe terminal automatically detects network baud rate settings and can assign an available node address during initial connection. Its built-in “Who” scanning feature identifies active nodes on the DeviceNet segment, simplifying commissioning and maintenance activities.\u003c\/p\u003e\n\u003cp\u003eTechnicians can navigate directly to parameter numbers for faster editing, monitor live I\/O messaging, and inspect communication diagnostics without disconnecting field devices from the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCommon industrial uses include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDeviceNet network commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor starter configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload relay parameter adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField-level diagnostics and troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDevice replacement and setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance verification during shutdowns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortable service tool for DeviceNet systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat is the primary purpose of the 193-DNCT?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e193-DNCT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used for configuring, monitoring, and troubleshooting DeviceNet-compatible devices directly from the field without requiring a computer.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDoes the terminal support automatic network setup?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes. The unit supports both automatic baud-rate detection and automatic node address assignment.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhich communication cable is included?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe terminal includes the 193-CB1 one-meter DeviceNet communication cable.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCan the terminal monitor live network activity?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes. It supports I\/O monitoring, network statistics viewing, and DeviceNet diagnostic inspection.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43392198606938,"sku":"193-DNCT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/193-DNCT2.jpg?v=1779162202","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-193-dnct-devicenet-configuration-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}