Skip to content
Allen-Bradley 2080-OB4 Digital Output Plug-in Module

Allen-Bradley 2080-OB4 Digital Output Plug-in Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 2080-OB4

  • Condition: In stock

  • Product Type: Micro 820 Programmable Controller

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 358g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43791900344410,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2080-OB4","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 2080-OB4 Digital Output Plug-in Module","public_title":null,"options":["Default Title"],"price":12300,"weight":358,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 2080-OB4 Digital Output Plug-in Module

Configured for DC load switching execution in Micro800 PLC control networks, the Allen-Bradley 2080-OB4 (2080-OB4 Digital Output Plug-in Module) provides direct physical/electrical execution. The module provides four non-isolated 12/24 VDC sourcing transistor outputs for connection to low-power DC control devices.

Hardware Specifications

Parameter Specification
Model 2080-OB4
Brand Allen-Bradley / Rockwell Automation
Operating Temp -20 deg C to +65 deg C
Module Type Digital Output Plug-in Module
Controller Platform Micro800 PLC family
Number of Outputs 4 channels
Output Type Solid-state sourcing (PNP) transistor outputs
Nominal Operating Voltage 12 / 24 VDC
Operating Voltage Range 10.8 VDC to 28.8 VDC
Output Current Rating 0.5 A per channel
Surge Current 2.0 A for 10 ms
On-State Voltage Drop 0.5 VDC maximum at rated current
Off-State Leakage Current 1.0 mA maximum
Response Time Turn-on: less than 0.1 ms; Turn-off: less than 1.0 ms
Status Indicators 4 yellow LEDs, one per output channel
Wiring Category Signal / Control
Enclosure Rating IP20

Profinet / EtherNet-IP Deterministic Networks and I/O Density Scaling

The 2080-OB4 uses the Micro800 plug-in architecture to expand controller I/O capability without additional DIN rail mounting space. The module supports four discrete sourcing output channels with individual LED status indication for channel-level diagnostic observation. The solid-state transistor output design provides fast switching response for relay, solenoid, indicator, and actuator control circuits.

The plug-in connection maintains compact controller assembly requirements while allowing modular I/O density scaling within supported Micro800 controller configurations. Firmware compatibility must be verified between the controller base unit and installed plug-in module revision before commissioning.

Frequently Asked Questions (FAQ)

Q: Is the 2080-OB4 output module isolated between channels?
A: No. The provided specifications identify the outputs as non-isolated sourcing transistor channels. External circuit design should consider the common electrical reference requirements.

Q: Can the 2080-OB4 be installed in a separate DIN rail enclosure?
A: No. The module is designed as a plug-in module that mounts directly into an available plug-in slot on supported Micro800 controller base units.

Q: What type of loads can be connected to the output channels?
A: The outputs are designed for low-power 12/24 VDC DC loads such as relays, solenoids, indicators, and actuators within the specified current rating.

Field Installation Guidelines

Install the 2080-OB4 directly into a compatible Micro800 controller plug-in slot according to the controller installation manual. Confirm controller power is removed before module insertion or removal.

Use signal wiring practices appropriate for DC control circuits. Route output wiring separately from high-voltage power conductors to reduce electrical interference. Connect field devices according to the sourcing PNP output configuration and verify the common reference connection before energizing the system.

For panel installation, maintain proper grounding, enclosure protection, and wiring separation requirements. Use the removable terminal block for field wiring maintenance and replacement operations. Confirm LED channel status after commissioning to validate output operation.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured