{"product_id":"allen-bradley-2080-ov4-digital-output-plug-in-module","title":"Allen-Bradley 2080-OV4 Digital Output Plug-in Module","description":"\u003ch2\u003eAllen-Bradley 2080-OV4 Digital Output Plug-in Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for transistor output expansion in Micro800 controller platforms, the \u003cstrong\u003eAllen-Bradley 2080-OV4\u003c\/strong\u003e (\u003cstrong\u003e2080-OV4\u003c\/strong\u003e Digital Output Plug-in Module) provides direct physical\/electrical execution through four non-isolated sourcing outputs connected through a controller plug-in slot.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2080-OV4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Plug-in Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Compatibility\u003c\/td\u003e\n\u003ctd\u003eMicro820, Micro830, Micro850, Micro870\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4 transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor sourcing output (PNP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.8 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Surge Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A for 10 ms, maximum once every 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V continuous, basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Torque\u003c\/td\u003e\n\u003ctd\u003e0.22 to 0.25 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e0.14 to 1.5 mm2 solid or stranded copper wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and I\/O Expansion Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 2080-OV4 follows the Micro800 plug-in module architecture, allowing additional digital output channels without increasing the controller enclosure footprint. The module communicates through the controller internal plug-in interface and maintains local I\/O density scaling for compact automation assemblies. The removable terminal block supports field wiring access and replacement procedures without modifying the controller mounting arrangement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which Micro800 controllers support the 2080-OV4 module?\u003cbr\u003eA: The module is compatible with Micro820, Micro830, Micro850, and Micro870 controllers that provide an available plug-in slot.\u003c\/p\u003e\n\u003cp\u003eQ: What type of electrical loads can be connected to the output channels?\u003cbr\u003eA: The module provides sourcing transistor outputs designed for DC loads including relays, solenoids, and indicator devices within the specified voltage and current limits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 2080-OV4 provide isolated output channels?\u003cbr\u003eA: No. The module provides four non-isolated transistor outputs with a continuous isolation voltage rating of 50 V basic insulation type.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module directly into an available Micro800 controller plug-in slot according to the controller hardware manual. Confirm controller power is removed before insertion or removal of the module.\u003c\/p\u003e\n\u003cp\u003eUse copper conductors within the supported wire range and maintain correct polarity for sourcing PNP output connections. Route output wiring separately from high-voltage switching conductors where possible to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConnect cable shields according to the system grounding design and maintain proper enclosure grounding practices. Verify terminal block seating, conductor retention, and output load requirements before applying power.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43791987769434,"sku":"2080-OV4","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2080-OV42.jpg?v=1785998059","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2080-ov4-digital-output-plug-in-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}