Skip to content
Allen-Bradley 2094-BC01-MP5-S Kinetix 6000 Integrated Axis Module

Allen-Bradley 2094-BC01-MP5-S Kinetix 6000 Integrated Axis Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 2094-BC01-MP5-S

  • Condition: In stock

  • Product Type: 10.1-inch Widescreen HMI Panel

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 5443g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43792143908954,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2094-BC01-MP5-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 2094-BC01-MP5-S Kinetix 6000 Integrated Axis Module","public_title":null,"options":["Default Title"],"price":12300,"weight":5443,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 2094-BC01-MP5-S Kinetix 6000 Integrated Axis Module

Configured for AC/DC power conversion and servo axis power management in the Kinetix 6000 Motion Control System, the Allen-Bradley 2094-BC01-MP5-S (2094-BC01-MP5-S Integrated Axis Module) provides direct physical/electrical execution for 400 Volt class drive applications.

Hardware Specifications

Parameter Specification
Model 2094-BC01-MP5-S
Brand Allen-Bradley
Product Type Integrated Axis Module (IAM)
Product Line Kinetix 6000
Module Type IAM 400 Volt Class
Origin United States
Weight 12.00 lbs
Dimensions Minimum enclosure depth: 198 mm (7.8 in)
Power Consumption 6 kW continuous power output to bus
AC Input Voltage 324-528 Vrms, 3 Phase
Nominal AC Input Voltage 360 / 480 VAC
AC Input Frequency 47-63 Hz
AC Input Current 10.0 A nominal RMS
Maximum Inrush Current 11.0 A, 0-peak
DC Input Voltage (Common Bus Follower) 458-747 VDC
DC Input Current (Common Bus Follower) 9.0 A
Continuous Output Current to Bus 9.0 A
Peak Power Output 12 kW
Internal Shunt Continuous Power 50 W
Internal Shunt Peak Power 5.6 kW
Internal Shunt Resistor 115 Ohms
Efficiency 97%
Safety Function Integrated Safe Torque Off (STO)
Mounting Location Power Rail
Installation Clearance 50.8 mm (2.0 in)
Communication Interface SERCOS

EtherNet/IP and Motion Control Drive Integration Characteristics

The 2094-BC01-MP5-S is designed for integration within the Kinetix 6000 power rail architecture. The IAM module performs the main AC input conversion and DC bus distribution functions required for connected axis modules. The module supports common-bus follower operation through a 458-747 VDC input range and provides a DC bus interface for coordinated multi-axis motion configurations.

The Kinetix 6000 platform uses modular power rail construction, allowing axis modules to share DC bus power distribution. The module supports SERCOS-based motion communication and provides integrated Safe Torque Off (STO) functionality for removal of torque-producing energy from connected motor drives.

Firmware and Backplane Compatibility

The module operates as part of the Kinetix 6000 modular drive system, where firmware compatibility and hardware configuration are managed through the controller and motion network architecture. The IAM module requires correct power rail installation and compatible axis module configuration to maintain DC bus operation and motion synchronization.

Frequently Asked Questions

Q: What input power configuration is required for the 2094-BC01-MP5-S?
A: The module requires a 3-phase AC input supply rated at 324-528 Vrms, with nominal operation at 360 / 480 VAC and an input frequency range of 47-63 Hz.

Q: Can the module operate in a common DC bus system?
A: Yes. The 2094-BC01-MP5-S supports common-bus follower operation using a 458-747 VDC input range.

Q: Does the module include a safety shutdown function?
A: Yes. The module includes an integrated Safe Torque Off (STO) function for disabling torque generation at the drive level.

Field Installation Guidelines

  • Install the IAM module on the designated Kinetix 6000 Power Rail mounting location.
  • Maintain the specified enclosure depth and installation clearance requirements to support mechanical installation and airflow conditions.
  • Connect AC input wiring according to the specified 3-phase voltage and frequency ratings.
  • For common DC bus configurations, verify DC bus voltage compatibility before connection.
  • Separate power wiring from low-level signal wiring to reduce electrical noise coupling.
  • Apply appropriate grounding and shielding practices for SERCOS communication cables and motor feedback wiring.
  • Verify STO wiring continuity and safety circuit operation before enabling motor power.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products