{"product_id":"allen-bradley-20ac8p7a0aynanc0-powerflex-70-ac-drive","title":"Allen-Bradley 20AC8P7A0AYNANC0 PowerFlex 70 AC Drive","description":"\u003ch2\u003eAllen-Bradley 20AC8P7A0AYNANC0 PowerFlex 70 AC Drive\u003c\/h2\u003e\n\u003cp\u003eConfigured for adjustable frequency motor control in PowerFlex 70 AC drive systems, the \u003cstrong\u003eAllen-Bradley 20AC8P7A0AYNANC0\u003c\/strong\u003e (\u003cstrong\u003e20AC8P7A0AYNANC0\u003c\/strong\u003e AC Drive) provides direct physical and electrical execution for 400 VAC three-phase motor applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e20AC8P7A0AYNANC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.92 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 kW \/ 5 HP nominal output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eAdjustable Frequency AC Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e400 VAC, 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e8.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePanel Mount - IP 20, NEMA\/UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Module\u003c\/td\u003e\n\u003ctd\u003eBlank Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake Configuration\u003c\/td\u003e\n\u003ctd\u003eBrake IGBT Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Drive Control Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 70 platform supports industrial drive control architectures through configurable communication options. The 20AC8P7A0AYNANC0 model is specified with no integrated network interface and operates through local control wiring and drive parameters. The Enhanced Control configuration provides adjustable frequency operation without encoder feedback, using internal drive control algorithms for motor speed regulation.\u003c\/p\u003e\n\u003cp\u003eThe drive hardware uses PowerFlex 70 firmware compatibility rules for parameter management, control configuration, and replacement module matching. Installation procedures require verification of firmware revision compatibility before control configuration transfer.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 20AC8P7A0AYNANC0 include an operator keypad module?\u003cbr\u003eA: No. This model is supplied with a blank cover interface module instead of a Human Interface Module (HIM).\u003c\/p\u003e\n\u003cp\u003eQ: Does this drive provide encoder feedback input?\u003cbr\u003eA: No. The specified configuration is a no-feedback AC drive with Enhanced Control operation.\u003c\/p\u003e\n\u003cp\u003eQ: Is an internal brake resistor installed in this model?\u003cbr\u003eA: No. The drive includes a brake IGBT circuit but does not include an internal brake resistor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the drive in a panel enclosure according to the specified IP 20 and NEMA\/UL Type 1 environmental requirements. Maintain separation between motor power conductors and low-level control wiring to reduce electrical noise coupling.\u003c\/p\u003e\n\u003cp\u003eConnect protective earth grounding according to industrial drive installation practices. Use appropriate cable shielding methods for control signal wiring, with the shield termination arranged to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify input voltage, phase configuration, motor current settings, and braking circuit requirements before energizing the drive. Confirm that parameter values match the connected motor characteristics before placing the drive into operation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43792380559450,"sku":"20AC8P7A0AYNANC0","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/20AC8P7A0AYNANC02.jpg?v=1786005331","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-20ac8p7a0aynanc0-powerflex-70-ac-drive","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}