{"product_id":"allen-bradley-2198-h008-ers-kinetix-5500-servo-drive","title":"Allen-Bradley 2198-H008-ERS Kinetix 5500 Servo Drive","description":"\u003ch2\u003eAllen-Bradley 2198-H008-ERS Kinetix 5500 Servo Drive\u003c\/h2\u003e\n\u003cp\u003eConfigured for servo motor current control and motion execution in EtherNet\/IP industrial control systems, the \u003cstrong\u003eAllen-Bradley 2198-H008-ERS\u003c\/strong\u003e (\u003cstrong\u003e2198-H008-ERS\u003c\/strong\u003e Kinetix 5500 Servo Drive) provides direct physical\/electrical execution. The drive accepts 195-264 V rms and 324-528 V rms AC input ranges and delivers controlled three-phase motor output with integrated hardwired Safe Torque Off capability.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2198-H008-ERS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.11 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eKinetix 5500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e195-264 V rms single-phase \/ three-phase (240 V nominal); 324-528 V rms three-phase (480 V nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 2.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Output Voltage\u003c\/td\u003e\n\u003ctd\u003e0-460 V rms, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Output Frequency\u003c\/td\u003e\n\u003ctd\u003e0-590 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e2.5 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current (0-peak)\u003c\/td\u003e\n\u003ctd\u003e3.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output Current (rms)\u003c\/td\u003e\n\u003ctd\u003e6.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output Current (0-peak)\u003c\/td\u003e\n\u003ctd\u003e8.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Power\u003c\/td\u003e\n\u003ctd\u003e0.5 kW at 195-264 V rms single-phase; 0.8 kW at 195-264 V rms three-phase; 1.6 kW at 324-528 V rms three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Loop Bandwidth\u003c\/td\u003e\n\u003ctd\u003e300 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Loop Bandwidth\u003c\/td\u003e\n\u003ctd\u003e1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current Rating\u003c\/td\u003e\n\u003ctd\u003e200,000 A rms symmetrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function\u003c\/td\u003e\n\u003ctd\u003eHardwired Safe Torque Off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFrame Size 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Safety over EtherNet\/IP\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Motion Control and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2198-H008-ERS operates within the Kinetix 5500 servo platform for coordinated motion applications using EtherNet\/IP communication architecture. The drive supports deterministic network-based motion commands when integrated with compatible Allen-Bradley controllers and motion configurations. Firmware compatibility must be verified against the controller revision, motion software version, and system configuration before commissioning.\u003c\/p\u003e\n\u003cp\u003eThe Kinetix 5500 platform uses modular industrial control integration with scalable I\/O and drive axis configurations. Backplane bus communication velocity, network cycle performance, and firmware flash compatibility depend on the associated controller and system revision.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2198-H008-ERS support integrated Safety over EtherNet\/IP?\u003cbr\u003eA: No. This model provides a hardwired Safe Torque Off (STO) safety function and does not include Integrated Safety over EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003eQ: What are the motor output electrical limits of the drive?\u003cbr\u003eA: The drive provides 0-460 V rms three-phase motor output with a continuous current rating of 2.5 A rms and peak output current of 6.25 A rms.\u003c\/p\u003e\n\u003cp\u003eQ: Can the servo drive be installed with direct consideration of firmware compatibility?\u003cbr\u003eA: Yes. Firmware revision compatibility between the drive, controller, and motion configuration must be confirmed before firmware updates or system commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 2198-H008-ERS in accordance with the Kinetix 5500 installation requirements and applicable industrial electrical standards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify AC input voltage configuration before energizing the drive. The unit supports different voltage ranges depending on single-phase or three-phase supply selection.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding practices for protective earth and cable shield termination to reduce electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eRoute motor power cables separately from low-level feedback and communication wiring to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfirm motor feedback wiring, connector orientation, and shielding before applying control power.\u003c\/li\u003e\n\u003cli\u003eEnsure the hardwired STO circuit is correctly connected and validated before enabling axis motion.\u003c\/li\u003e\n\u003cli\u003eMaintain proper enclosure ventilation and mounting clearance according to the installation manual requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43796685193306,"sku":"2198-H008-ERS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2198-H008-ERS2.jpg?v=1786083207","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2198-h008-ers-kinetix-5500-servo-drive","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}