{"product_id":"allen-bradley-2711-b6c8l1-panelview-600-operator-interface-terminal","title":"Allen-Bradley 2711-B6C8L1 PanelView 600 Operator Interface Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-B6C8L1 PanelView 600 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-B6C8L1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-B6C8L1\u003c\/strong\u003e PanelView 600 Operator Interface Terminal, operates as a dedicated hardware component for operator command input and process visualization within Allen-Bradley DH+ communication networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-B6C8L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePanelView 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor Active-Matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.5 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eTouch Screen and Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Keys\u003c\/td\u003e\n\u003ctd\u003e10 Function Keys (F1-F10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDH+ (Data Highway Plus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232 Printer Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W maximum, 1.0 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB Application Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 12, NEMA 13, NEMA 4X, IP54\/IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.06 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and PanelView Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711-B6C8L1 uses the PanelView Standard architecture with DH+ communication capability for data exchange between the operator terminal and Allen-Bradley control systems. The terminal processes operator inputs from the keypad and touch interface while displaying application data through the color TFT display.\u003c\/p\u003e\n\u003cp\u003eThe hardware provides an RS-232 port for printer communication functions and supports PanelBuilder32 software for application configuration and transfer operations. The communication path depends on the connected controller network configuration and installed application parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2711-B6C8L1 support Ethernet communication?\u003cbr\u003eA: No. The available communication interface is DH+ (Data Highway Plus) with an additional RS-232 printer port. Ethernet communication is not specified for this model.\u003c\/p\u003e\n\u003cp\u003eQ: What input methods are available on the terminal?\u003cbr\u003eA: The terminal combines a touch screen interface with a physical keypad containing 10 function keys from F1 to F10.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply is required for the 2711-B6C8L1?\u003cbr\u003eA: The unit requires a 24 VDC input supply with a documented operating range of 18 VDC to 32 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 2711-B6C8L1 in a panel cutout suitable for the PanelView 600 enclosure design. Verify that the mounting surface provides mechanical support and maintains the specified enclosure protection level after installation.\u003c\/p\u003e\n\u003cp\u003eUse a regulated 24 VDC power source with appropriate circuit protection. Route DC power wiring separately from high-voltage conductors and high-current switching lines to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eFor DH+ communication wiring, follow Allen-Bradley Data Highway Plus network installation practices, including correct cable routing, termination, and shielding procedures. Connect cable shields according to the control cabinet grounding design to minimize communication noise.\u003c\/p\u003e\n\u003cp\u003eThe RS-232 connection should be installed with proper cable length control and separation from sources of electromagnetic interference. Replaceable backlight servicing should only be performed with power removed from the terminal.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43817038774362,"sku":"2711-B6C8L1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-B6C8L12.jpg?v=1786347796","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-b6c8l1-panelview-600-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}