{"product_id":"allen-bradley-2711-k10c8-panelview-1000-operator-terminal","title":"Allen-Bradley 2711-K10C8 PanelView 1000 Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-K10C8 PanelView 1000 Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for operator interface data entry and visualization in PanelView Standard control networks, the \u003cstrong\u003eAllen-Bradley 2711-K10C8\u003c\/strong\u003e (\u003cstrong\u003e2711-K10C8\u003c\/strong\u003e Operator Terminal) provides direct physical\/electrical execution through keypad input, color TFT display output, DH+ communication, and RS-232 printer connectivity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K10C8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in available data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000 Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000 \/ PanelView Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Keys\u003c\/td\u003e\n\u003ctd\u003e16 programmable keys (F1-F16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eData Highway Plus (DH+) and RS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e310 KB runtime memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e1008 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATA Memory Card\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13 or 4X operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Network Interface and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2711-K10C8 integrates PanelView Standard operator interface functions with Data Highway Plus communication for controller data exchange. The terminal provides keypad-based command entry, graphical display processing, and application storage through internal memory resources.\u003c\/p\u003e\n\u003cp\u003eThe unit supports firmware flash compatibility within the applicable PanelView Standard platform. Application transfer and maintenance procedures require compatibility between terminal firmware, development software, and connected controller communication settings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are available on the 2711-K10C8?\u003cbr\u003eA: The terminal provides Data Highway Plus (DH+) communication and an RS-232 printer port interface.\u003c\/p\u003e\n\u003cp\u003eQ: What type of operator input does the terminal support?\u003cbr\u003eA: The unit uses a keypad input structure with sixteen programmable function keys labeled F1 through F16.\u003c\/p\u003e\n\u003cp\u003eQ: Can the terminal use removable memory storage?\u003cbr\u003eA: The 2711-K10C8 supports ATA memory card storage for applicable application transfer and storage functions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the operator terminal in a panel cutout that matches the specified enclosure requirements and mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect the 85-264 VAC power supply using the approved terminal block and verify wiring polarity before energization.\u003c\/li\u003e\n\u003cli\u003eRoute DH+ communication wiring separately from high-voltage conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cable shielding and connect shields according to the site grounding practice.\u003c\/li\u003e\n\u003cli\u003eVerify RS-232 wiring configuration before connecting external printer or serial equipment.\u003c\/li\u003e\n\u003cli\u003eConfirm application file compatibility and terminal firmware revision before loading operating projects.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43825042391130,"sku":"2711-K10C8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-K10C82.jpg?v=1786437175","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-k10c8-panelview-1000-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}