{"product_id":"allen-bradley-2711-k10g8-panelview-1000-standard-operator-terminal","title":"Allen-Bradley 2711-K10G8 PanelView 1000 Standard Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-K10G8 PanelView 1000 Standard Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-K10G8\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-K10G8\u003c\/strong\u003e PanelView 1000 Standard Operator Terminal, operates as a dedicated hardware component for operator interface execution through keypad input, monochrome display visualization, and DH+ communication within Allen-Bradley control system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K10G8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000 Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eBlack\/white monochrome grayscale display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003e16 programmable function keys (F1-F16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eData Highway Plus (DH+), RS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e310 KB runtime; 1008 KB nonvolatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATA Memory Card\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13 or 4X operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e211 x 158 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Life\u003c\/td\u003e\n\u003ctd\u003e50,000 hr half-life at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Control System Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711-K10G8 uses Data Highway Plus (DH+) communication for data exchange with Allen-Bradley programmable controllers and related automation devices. The RS-232 interface provides printer communication capability. The terminal processes operator input through the integrated keypad and transfers display data through the PanelView Standard runtime environment.\u003c\/p\u003e\n\u003cp\u003eThe PanelView 1000 platform supports application object storage, text resources, and bitmap elements through internal nonvolatile memory and optional ATA memory card media. Firmware compatibility must be verified before application transfer or memory replacement operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2711-K10G8 support Ethernet communication?\u003cbr\u003eA: No. The supplied specifications identify DH+ and RS-232 printer communication interfaces. Ethernet communication is not listed for this terminal.\u003c\/p\u003e\n\u003cp\u003eQ: What type of operator input is available on this terminal?\u003cbr\u003eA: The terminal uses a keypad input structure with 16 programmable function keys labeled F1 through F16.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply range is required for the 2711-K10G8?\u003cbr\u003eA: The terminal accepts 85-264 VAC input power at 47-63 Hz.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 2711-K10G8 in a compatible panel cutout according to the mechanical installation requirements of the PanelView Standard terminal family. Verify that the enclosure rating matches the installation environment before mounting.\u003c\/p\u003e\n\u003cp\u003eUse appropriate grounding practices for the operator interface enclosure and connect communication cable shields according to the DH+ network wiring requirements. Separate communication wiring from high-voltage power conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConfirm the AC power source is within the specified input voltage range before energizing the terminal. Ensure function key legends, backlight components, memory media, and interface modules are installed only with compatible PanelView Standard accessories.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43825061363802,"sku":"2711-K10G8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-K10G82.jpg?v=1786437449","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-k10g8-panelview-1000-standard-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}