{"product_id":"allen-bradley-2711-k6c10-panelview-600-operator-terminal","title":"Allen Bradley 2711-K6C10 PanelView 600 Operator Terminal","description":"\u003ch2\u003eAllen Bradley 2711-K6C10 PanelView 600 Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for operator interface execution in DeviceNet industrial control networks, the \u003cstrong\u003eAllen Bradley 2711-K6C10\u003c\/strong\u003e (\u003cstrong\u003e2711-K6C10\u003c\/strong\u003e PanelView 600 operator terminal) provides direct physical\/electrical execution through keypad input, color display visualization, and serial communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe available documentation identifies \u003cstrong\u003e2711-K6C10\u003c\/strong\u003e as a complete catalog number within the Allen Bradley PanelView Standard product family. No individual catalog suffix breakdown is specified in the provided technical data.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K6C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.23 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interface\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDeviceNet, RS-232 Printer Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e240 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e2711-NL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Interface Type\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Technology\u003c\/td\u003e\n\u003ctd\u003eColor operator display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input Method\u003c\/td\u003e\n\u003ctd\u003eIntegrated keypad interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Communication\u003c\/td\u003e\n\u003ctd\u003eDeviceNet communication port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Communication\u003c\/td\u003e\n\u003ctd\u003eRS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Cable\u003c\/td\u003e\n\u003ctd\u003e2711-NC14 communication cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Series\u003c\/td\u003e\n\u003ctd\u003eA, B, C, D, E, F, G, H, I, J, K, L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Control Network Interface\u003c\/h3\u003e\n\u003cp\u003eThe 2711-K6C10 uses DeviceNet communication for data exchange with Allen Bradley control architectures. The terminal provides keypad-driven operator commands and color display feedback through its integrated human-machine interface hardware. RS-232 communication is available for printer interface functions and serial data transfer requirements.\u003c\/p\u003e\n\u003cp\u003eThe PanelView 600 platform supports industrial operator control applications requiring discrete user input, status visualization, and controller network communication. Configuration compatibility depends on the terminal firmware revision and connected control system requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2711-K6C10 support Ethernet communication directly?\u003cbr\u003eA: No. The provided specifications identify DeviceNet and RS-232 Printer Port communication interfaces. Ethernet communication capability is not listed for this catalog number.\u003c\/p\u003e\n\u003cp\u003eQ: What type of operator input is supported by the 2711-K6C10?\u003cbr\u003eA: The unit uses an integrated keypad interface for operator command entry.\u003c\/p\u003e\n\u003cp\u003eQ: What power input range is required for the terminal?\u003cbr\u003eA: The specified input power range is 85-264 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the terminal in a panel cutout according to the mechanical mounting requirements defined by the PanelView 600 installation documentation.\u003c\/li\u003e\n\u003cli\u003eUse the specified communication cable type when connecting compatible DeviceNet or serial communication equipment.\u003c\/li\u003e\n\u003cli\u003eRoute DeviceNet and RS-232 wiring separately from high-voltage power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eApply appropriate cable shielding and grounding practices according to industrial communication installation standards.\u003c\/li\u003e\n\u003cli\u003eVerify the AC power supply voltage range before energizing the terminal.\u003c\/li\u003e\n\u003cli\u003eConfirm firmware compatibility between the terminal and the connected controller system before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43825194860634,"sku":"2711-K6C10","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-K5A5H1.jpg?v=1786439398","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-k6c10-panelview-600-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}