{"id":43825223860314,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2711-KC1\/F","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 2711-KC1\/F PanelView 1200 Operator Terminal","public_title":null,"options":["Default Title"],"price":12300,"weight":9072,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 2711-KC1/F PanelView 1200 Operator Terminal

The Allen-Bradley 2711-KC1/F, also cataloged as the 2711-KC1 PanelView 1200 Operator Terminal, operates as a dedicated hardware component for operator data entry, machine status display, and control signal exchange within Allen-Bradley Remote I/O industrial automation networks.

Hardware Specifications

Parameter Specification
Model 2711-KC1/F
Brand Allen-Bradley / Rockwell Automation
Origin United States
Weight 20 lbs
Operating Temp 0 deg C to 50 deg C
Power Consumption Approximately 100 VA maximum
Product Family PanelView 1200 Operator Terminals
Display Type 12-inch Color CRT Display
Input Method Stainless-steel tactile membrane keypad
Function Keys 16 function keys (F1 to F16)
Keypad Life 2 million presses
Communication Interface Remote I/O (RIO), RS-232 printer interface
Input Voltage 90-132 VAC / 180-264 VAC automatic selection
Input Frequency 47-63 Hz
Memory Type RAM with non-volatile storage support
Configuration Software PanelBuilder 1200
Display Format 24 rows x 80 columns
Enclosure Rating NEMA Type 4X (Indoor Use Only), NEMA 12, NEMA 13
Storage Temperature -40 deg C to 85 deg C
Relative Humidity 5% to 95% non-condensing

Industrial Control Network Integration

The 2711-KC1/F integrates with Allen-Bradley PLC communication architectures through Remote I/O connectivity. The terminal exchanges operator commands, status information, and alarm data with controller systems including PLC-5 and SLC controller families through supported network interfaces.

The PanelView 1200 Series F hardware revision incorporates updated internal board assemblies and power supply components compared with earlier series revisions. The terminal maintains compatibility with PanelBuilder 1200 configuration environments for application transfer and maintenance operations.

The keypad-based operator interface provides direct mechanical input through tactile membrane switches, allowing numeric entry, function key activation, and machine command execution without touchscreen interaction.

Frequently Asked Questions

Q: Does the 2711-KC1/F support touchscreen operation?
A: No. The 2711-KC1/F uses a tactile membrane keypad interface with function keys and alphanumeric input capability.

Q: What communication network is supported by the terminal?
A: The terminal supports Remote I/O communication for connection with compatible Allen-Bradley controller systems. RS-232 is available for printer-related communication functions.

Q: Is the 2711-KC1/F compatible with newer PanelView platforms?
A: The 2711-KC1/F is based on the PanelView 1200 architecture and requires PanelBuilder 1200 software for application configuration and maintenance.

Field Installation Guidelines

Install the 2711-KC1/F in a panel cutout according to the mechanical mounting requirements of the PanelView 1200 terminal enclosure. Confirm that the mounting surface provides adequate mechanical support for the CRT display assembly.

Connect the AC power input using industrial wiring practices. Separate power conductors from communication cables to reduce electrical interference. Apply appropriate grounding methods between the terminal chassis and the control panel grounding system.

For Remote I/O connections, use shielded communication cable where required by the installation environment. Terminate cable shields according to the controller network grounding specification and avoid routing communication wiring parallel to high-current motor or drive conductors.

Before commissioning, verify supply voltage selection, communication addressing, keypad operation, display response, and application download compatibility through the PanelBuilder 1200 configuration environment.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products