{"product_id":"allen-bradley-2711-t10c15-panelview-1000-operator-terminal","title":"Allen-Bradley 2711-T10C15 PanelView 1000 Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-T10C15 PanelView 1000 Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for operator monitoring and command entry through ControlNet, the \u003cstrong\u003eAllen-Bradley 2711-T10C15\u003c\/strong\u003e (\u003cstrong\u003e2711-T10C15 PanelView 1000 Operator Terminal\u003c\/strong\u003e) provides direct touchscreen interaction with connected PLC systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10C15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.99 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active-matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels, VGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Communication\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Communication\u003c\/td\u003e\n\u003ctd\u003eRS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e55 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e310 KB flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12, 13, 4X indoor only, IP54\/IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003ePanelBuilder32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Replacement\u003c\/td\u003e\n\u003ctd\u003e2711-NC13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControlNet Communication and PanelView Interface\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10C15 provides ControlNet communication for deterministic data exchange with compatible Allen-Bradley controller platforms.\u003c\/p\u003e\n\u003cp\u003eSupported controller families identified in the supplied data include ControlLogix, PLC-5, and SLC 500 systems.\u003c\/p\u003e\n\u003cp\u003eThe RS-232 printer port provides an auxiliary serial interface separate from the primary ControlNet connection.\u003c\/p\u003e\n\u003cp\u003ePanelBuilder32 provides application configuration for screen objects, operator controls, communication parameters, and terminal application data.\u003c\/p\u003e\n\u003cp\u003eThe 640 x 480 VGA display uses an analog resistive touchscreen for direct operator input and navigation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication interface does the 2711-T10C15 use for controller data exchange?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The terminal provides a ControlNet communication port for data exchange with compatible PLC controller platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input power does the 2711-T10C15 require?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The terminal accepts 85-264 VAC input power across a specified frequency range of 47-63 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the touchscreen operate independently of the ControlNet connection?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The resistive touchscreen provides local input, while controller data exchange depends on the configured communication interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal within an enclosure compatible with its specified NEMA and IP protection classifications.\u003c\/p\u003e\n\u003cp\u003eVerify supply voltage and frequency before energizing the terminal, using wiring practices appropriate for industrial AC equipment.\u003c\/p\u003e\n\u003cp\u003eRoute ControlNet communication wiring separately from high-current conductors and sources of substantial electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable shielding and grounding according to the applicable ControlNet installation requirements and plant wiring standards.\u003c\/p\u003e\n\u003cp\u003eDo not apply mechanical force to the touchscreen surface, connectors, or communication ports during panel installation.\u003c\/p\u003e\n\u003cp\u003eConfirm enclosure clearances and environmental conditions before installation, particularly where the specified operating temperature range applies.\u003c\/p\u003e\n\u003cp\u003eConfigure communication parameters and terminal applications through PanelBuilder32 before connecting the terminal to operational controller networks.\u003c\/p\u003e\n\u003cp\u003eVerify the ControlNet connection, touchscreen response, display operation, and auxiliary RS-232 interface during commissioning.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43861928247386,"sku":"2711-T10C15","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-T10C152.jpg?v=1787042008","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-t10c15-panelview-1000-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}