{"product_id":"allen-bradley-2711-t10c8-panelview-1000-standard-operator-terminal","title":"Allen-Bradley 2711-T10C8 PanelView 1000 Standard Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-T10C8 PanelView 1000 Standard Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touch-based operator interface functions in a PanelView 1000 system, the \u003cstrong\u003eAllen-Bradley 2711-T10C8\u003c\/strong\u003e (\u003cstrong\u003e2711-T10C8\u003c\/strong\u003e operator terminal) provides direct display and operator input through a 10.1 in. color touchscreen. The terminal accepts 85 to 264 VAC at 47 to 63 Hz and provides Data Highway Plus and RS-232 printer communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10C8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000 Standard Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source Rating\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e211 x 158 mm (8.3 x 6.2 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive Matrix TFT with CCF backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Color\u003c\/td\u003e\n\u003ctd\u003eMulti-Color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Input\u003c\/td\u003e\n\u003ctd\u003eAnalog-resistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Matrix\u003c\/td\u003e\n\u003ctd\u003e24 columns x 16 rows, 384 cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Cell Size\u003c\/td\u003e\n\u003ctd\u003e26 x 30 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e1008K bytes for application screens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e256 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eData Highway Plus (DH+); RS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e39 W (132 BTU\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13 or Type 4X operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e100,000 hr LED backlight life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView 1000 Communication and Display Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10C8 uses a 10.1 in. active matrix TFT display with 640 x 480 pixel resolution and multi-color graphics. The analog-resistive touchscreen provides operator input through a 24-column by 16-row touch matrix.\u003c\/p\u003e\n\u003cp\u003eThe supplied specifications identify Data Highway Plus as the primary terminal communication interface. An RS-232 port is provided for printer communication. No Profinet or EtherNet\/IP interface is specified for this model.\u003c\/p\u003e\n\u003cp\u003eThe terminal accepts 85 to 264 VAC over a 47 to 63 Hz input range. Therefore, field wiring must remain within the stated supply limits and follow the applicable installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are specified for the 2711-T10C8?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data specifies Data Highway Plus (DH+) communication and an RS-232 port for printer connection.\u003c\/p\u003e\n\u003cp\u003eQ: What touchscreen technology does the 2711-T10C8 use?\u003c\/p\u003e\n\u003cp\u003eA: The terminal uses an analog-resistive touchscreen with a 24-column by 16-row matrix containing 384 touch cells.\u003c\/p\u003e\n\u003cp\u003eQ: Does the supplied specification define hot-swap operation or firmware compatibility?\u003c\/p\u003e\n\u003cp\u003eA: No hot-swap capability or firmware compatibility requirements are specified in the provided technical data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the terminal model and nameplate voltage range before connecting the AC supply.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installed supply remains within the specified 85 to 264 VAC input range.\u003c\/li\u003e\n\u003cli\u003eRoute AC power conductors separately from communication and low-level signal wiring where practical.\u003c\/li\u003e\n\u003cli\u003eUse appropriate protective grounding and bonding methods for the enclosure and installation environment.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between DH+ communication wiring and high-voltage conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate communication wiring according to the applicable DH+ network wiring requirements and controller architecture.\u003c\/li\u003e\n\u003cli\u003eAvoid applying mechanical force to the resistive touchscreen during panel installation or enclosure assembly.\u003c\/li\u003e\n\u003cli\u003eVerify enclosure sealing and mounting conditions when the installation requires NEMA Type 12\/13 or Type 4X protection.\u003c\/li\u003e\n\u003cli\u003eProvide adequate ventilation around the terminal and account for the specified 39 W heat dissipation.\u003c\/li\u003e\n\u003cli\u003eDo not perform firmware replacement or configuration changes unless compatibility with the installed PanelView 1000 environment has been verified.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43862297378906,"sku":"2711-T10C8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-T10C82.jpg?v=1787045662","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-t10c8-panelview-1000-standard-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}