{"id":43862297378906,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2711-T10C8","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 2711-T10C8 PanelView 1000 Standard Operator Terminal","public_title":null,"options":["Default Title"],"price":12300,"weight":3629,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 2711-T10C8 PanelView 1000 Standard Operator Terminal

Configured for touch-based operator interface functions in a PanelView 1000 system, the Allen-Bradley 2711-T10C8 (2711-T10C8 operator terminal) provides direct display and operator input through a 10.1 in. color touchscreen. The terminal accepts 85 to 264 VAC at 47 to 63 Hz and provides Data Highway Plus and RS-232 printer communication.

Hardware Specifications

Parameter Specification
Model 2711-T10C8
Brand Allen-Bradley
Product Type PanelView 1000 Standard Operator Terminal
Product Family PanelView Standard Terminals
Product Line PanelView 1000
Weight 8 lb
Operating Temp 0 to 55 deg C (32 to 131 deg F)
Power Consumption Not specified in provided data
Supply Voltage 85 to 264 VAC
Power Source Rating 100 to 240 VAC
Input Frequency 47 to 63 Hz
Display Size 10.1 in.
Display Area 211 x 158 mm (8.3 x 6.2 in.)
Resolution 640 x 480 pixels
Display Type Active Matrix TFT with CCF backlight
Display Color Multi-Color
Touch Input Analog-resistive touchscreen
Touch Matrix 24 columns x 16 rows, 384 cells
Touch Cell Size 26 x 30 pixels
Application Memory 1008K bytes for application screens
Memory 256 KB
Communication Ports Data Highway Plus (DH+); RS-232 printer port
Heat Dissipation 39 W (132 BTU/hr)
Enclosure NEMA Type 12/13 or Type 4X operator interface
Backlight 100,000 hr LED backlight life

PanelView 1000 Communication and Display Characteristics

The 2711-T10C8 uses a 10.1 in. active matrix TFT display with 640 x 480 pixel resolution and multi-color graphics. The analog-resistive touchscreen provides operator input through a 24-column by 16-row touch matrix.

The supplied specifications identify Data Highway Plus as the primary terminal communication interface. An RS-232 port is provided for printer communication. No Profinet or EtherNet/IP interface is specified for this model.

The terminal accepts 85 to 264 VAC over a 47 to 63 Hz input range. Therefore, field wiring must remain within the stated supply limits and follow the applicable installation requirements.

Frequently Asked Questions (FAQ)

Q: What communication interfaces are specified for the 2711-T10C8?

A: The supplied data specifies Data Highway Plus (DH+) communication and an RS-232 port for printer connection.

Q: What touchscreen technology does the 2711-T10C8 use?

A: The terminal uses an analog-resistive touchscreen with a 24-column by 16-row matrix containing 384 touch cells.

Q: Does the supplied specification define hot-swap operation or firmware compatibility?

A: No hot-swap capability or firmware compatibility requirements are specified in the provided technical data.

Field Installation Guidelines

  1. Verify the terminal model and nameplate voltage range before connecting the AC supply.
  2. Confirm that the installed supply remains within the specified 85 to 264 VAC input range.
  3. Route AC power conductors separately from communication and low-level signal wiring where practical.
  4. Use appropriate protective grounding and bonding methods for the enclosure and installation environment.
  5. Maintain separation between DH+ communication wiring and high-voltage conductors to reduce electrical interference.
  6. Terminate communication wiring according to the applicable DH+ network wiring requirements and controller architecture.
  7. Avoid applying mechanical force to the resistive touchscreen during panel installation or enclosure assembly.
  8. Verify enclosure sealing and mounting conditions when the installation requires NEMA Type 12/13 or Type 4X protection.
  9. Provide adequate ventilation around the terminal and account for the specified 39 W heat dissipation.
  10. Do not perform firmware replacement or configuration changes unless compatibility with the installed PanelView 1000 environment has been verified.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products