{"product_id":"allen-bradley-2711-t10g8-panelview-1000-standard-operator-terminal","title":"Allen-Bradley 2711-T10G8 PanelView 1000 Standard Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-T10G8 PanelView 1000 Standard Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen operator input in the PanelView 1000 platform, the \u003cstrong\u003eAllen-Bradley 2711-T10G8\u003c\/strong\u003e (\u003cstrong\u003e2711-T10G8\u003c\/strong\u003e operator terminal) provides grayscale screen control with DH+ and RS-232 communications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10G8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000 Standard Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6 lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified; heat dissipation is 39 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive-matrix TFT with CCF backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Color\u003c\/td\u003e\n\u003ctd\u003e4 shades of gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e211 x 158 mm (8.3 x 6.2 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e100,000 hr stated life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Resolution\u003c\/td\u003e\n\u003ctd\u003e384 touch cells, arranged as 24 columns x 16 rows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Cell Size\u003c\/td\u003e\n\u003ctd\u003e26 x 30 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e1008K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed Memory\u003c\/td\u003e\n\u003ctd\u003e256 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eData Highway Plus (DH+); RS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13 or 4X operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e39 W (132 BTU\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDH+ and Operator Interface Communications\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10G8 provides a Data Highway Plus communication port for integration with compatible Allen-Bradley control architectures.\u003cbr\u003eAn RS-232 port is provided separately for printer communication and associated serial data functions.\u003cbr\u003eThe touchscreen divides the active interface into 384 addressable touch cells for operator command entry.\u003cbr\u003eTherefore, panel wiring should separate communication conductors from high-voltage and high-current switching circuits.\u003cbr\u003eCommunication cable shielding should follow the applicable DH+ installation requirements and established control-panel grounding practices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the 2711-T10G8 accept?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications state an input range of 85 to 264 VAC at 47 to 63 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which communication interfaces are provided on the 2711-T10G8?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The terminal provides one Data Highway Plus interface and one RS-232 printer port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 2711-T10G8 use a color display?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied data specifies a 10.1 in grayscale display with four shades of gray.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the terminal within the specified enclosure configuration and maintain clearance for wiring access.\u003cbr\u003eVerify the incoming AC voltage before connecting field power to the terminal.\u003cbr\u003eRoute DH+ communication wiring separately from AC power, contactor outputs, and high-noise switching conductors.\u003cbr\u003eTerminate cable shields according to the applicable communication network grounding practice without creating unintended ground-current paths.\u003cbr\u003eUse the specified RS-232 interface only for compatible serial equipment and observe the equipment wiring requirements.\u003cbr\u003eInspect touchscreen alignment and operator access before final panel closure.\u003cbr\u003eConfirm enclosure sealing and environmental protection after completing all field wiring.\u003cbr\u003eDo not apply or remove wiring while energized unless the applicable equipment documentation explicitly permits such work.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43867574894682,"sku":"2711-T10G8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-T10G82.jpg?v=1787121793","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-t10g8-panelview-1000-standard-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}