{"product_id":"allen-bradley-2711-t6c16l1-a-panelview-600-operator-interface-terminal","title":"Allen-Bradley 2711-T6C16L1\/A PanelView 600 Operator Interface Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-T6C16L1\/A PanelView 600 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-T6C16L1\/A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-T6C16L1\u003c\/strong\u003e PanelView 600 operator interface terminal, provides touchscreen HMI operation through DF1 RS-232 communication with Allen-Bradley PLC and SLC controllers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T6C16L1\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e152 x 185 x 82 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active-matrix TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.0 in (127 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eDF1 RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Connector\u003c\/td\u003e\n\u003ctd\u003e8-pin Mini-DIN \/ 9-pin D-sub depending on port configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 18 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W maximum, 1.0 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Flash Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e256 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eNon-replaceable halogen lamp, Catalog Number 2711-NC13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12, 13, 4X; indoor use only; IP54 \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView 600 Communication and HMI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T6C16L1\/A uses DF1 RS-232 communication for serial data exchange with compatible Allen-Bradley controllers. The communication interface provides point-to-point serial connectivity rather than Ethernet-based industrial networking.\u003c\/p\u003e\n\u003cp\u003eThe 5.0 in color active-matrix TFT display provides 320 x 234 pixel graphical presentation. Analog touchscreen input supplies operator navigation and process command entry.\u003c\/p\u003e\n\u003cp\u003eThe external 24 VDC supply accepts an 18 to 32 VDC operating range. Maximum specified consumption is 24 W, corresponding to 1.0 A at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eThe internal application memory consists of 240 KB flash memory with 256 KB RAM. The specified backlight uses a non-replaceable halogen lamp identified by Catalog Number 2711-NC13.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interface does the 2711-T6C16L1\/A provide?\u003c\/p\u003e\n\u003cp\u003eA: The terminal provides DF1 RS-232 communication, with connector configuration dependent on the installed port arrangement.\u003c\/p\u003e\n\u003cp\u003eQ: What DC supply range is specified for this terminal?\u003c\/p\u003e\n\u003cp\u003eA: The terminal operates from an external 24 VDC supply within an 18 to 32 VDC input range.\u003c\/p\u003e\n\u003cp\u003eQ: Can the touchscreen backlight be replaced?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specification identifies the backlight as a non-replaceable halogen lamp, Catalog Number 2711-NC13.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal within an enclosure compatible with the specified NEMA and IP protection requirements. Confirm the enclosure provides suitable environmental protection before energizing the equipment.\u003c\/p\u003e\n\u003cp\u003eProvide a regulated 24 VDC supply within the specified 18 to 32 VDC input range. Size the supply wiring for the maximum specified 1.0 A load and account for upstream voltage drop.\u003c\/p\u003e\n\u003cp\u003eRoute RS-232 communication wiring separately from high-voltage conductors, motor leads, and high-current switching circuits. Minimize parallel routing with high-noise conductors to reduce electromagnetic coupling.\u003c\/p\u003e\n\u003cp\u003eUse shielded serial cable where the installation environment contains significant electrical noise. Terminate cable shields according to the plant grounding standard and avoid creating unintended ground-current paths.\u003c\/p\u003e\n\u003cp\u003eVerify connector orientation and pin assignment before applying power or connecting the controller. Do not insert or remove communication connectors while energized unless the applicable installation procedure explicitly permits the operation.\u003c\/p\u003e\n\u003cp\u003eMaintain the specified 0 to 55 deg C operating range and 5 to 95 percent non-condensing humidity range. Provide adequate enclosure ventilation where internal heat accumulation could exceed the specified environmental limits.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43868587458650,"sku":"2711-T6C16L1\/A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-T6C16L11.jpg?v=1778664440","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-t6c16l1-a-panelview-600-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}