{"product_id":"allen-bradley-2711-t6c5l1-panelview-600-standard-operator-terminal","title":"Allen-Bradley 2711-T6C5L1 PanelView 600 Standard Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711-T6C5L1 PanelView 600 Standard Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for operator input and display functions in PanelView Standard terminal systems, the \u003cstrong\u003eAllen-Bradley 2711-T6C5L1\u003c\/strong\u003e (\u003cstrong\u003e2711-T6C5L1\u003c\/strong\u003e operator terminal) provides a color TFT display, resistive touchscreen, and RS-232 DH-485 communication interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T6C5L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView 600 Standard Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eA, B, C, D, E, F, G, H, I, J, K, L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive Matrix TFT with CCF backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e115 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Color\u003c\/td\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eField-replaceable CCF, 50,000 hr half-life at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Grid\u003c\/td\u003e\n\u003ctd\u003e16 columns x 8 rows, 128 cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Cell Size\u003c\/td\u003e\n\u003ctd\u003e20 x 30 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e190 KB application runtime; 240 KB nonvolatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDH-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003e2711-NC13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W maximum; 1.0 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e611320217858\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView 600 Operator Interface and DH-485 Communication\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T6C5L1 uses an analog resistive touchscreen for direct operator interaction with configured application objects.\u003c\/p\u003e\n\u003cp\u003eThe active matrix TFT display provides 320 x 240 pixel resolution within a 115 x 87 mm display area.\u003c\/p\u003e\n\u003cp\u003eThe RS-232 interface supports DH-485 communication for connection to compatible Allen-Bradley control architectures.\u003c\/p\u003e\n\u003cp\u003eThe supplied 2711-NC13 cable is identified as the communication cable for this terminal configuration.\u003c\/p\u003e\n\u003cp\u003eThe terminal accepts 18-32 VDC input power, with 24 VDC specified as the nominal supply voltage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage does the 2711-T6C5L1 require?\u003c\/p\u003e\n\u003cp\u003eA: The specified input range is 18-32 VDC, with 24 VDC as the nominal operating supply.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interface is provided?\u003c\/p\u003e\n\u003cp\u003eA: The terminal provides an RS-232 communication port configured for DH-485 protocol communication.\u003c\/p\u003e\n\u003cp\u003eQ: What type of operator input does this terminal use?\u003c\/p\u003e\n\u003cp\u003eA: The unit uses an analog resistive touchscreen with a 16-column by 8-row touch grid.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal in a mechanically stable panel location with adequate clearance for wiring and service access.\u003c\/p\u003e\n\u003cp\u003eVerify that the external DC supply remains within the specified 18-32 VDC input range during normal operation.\u003c\/p\u003e\n\u003cp\u003eUse wiring practices appropriate for low-voltage DC control equipment, and protect communication wiring from high-current conductors.\u003c\/p\u003e\n\u003cp\u003eRoute RS-232 communication wiring separately from motor, contactor, and other high-noise power circuits where practical.\u003c\/p\u003e\n\u003cp\u003eConnect cable shields according to the grounding architecture specified for the associated control system.\u003c\/p\u003e\n\u003cp\u003eVerify connector seating and cable strain relief before energizing the terminal.\u003c\/p\u003e\n\u003cp\u003eDo not apply or remove field wiring while energized unless the applicable equipment documentation explicitly permits that procedure.\u003c\/p\u003e\n\u003cp\u003eConfirm the configured DH-485 communication parameters and physical connection before placing the terminal into service.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43868669476954,"sku":"2711-T6C5L","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711-T6C5L2.jpg?v=1787130592","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711-t6c5l1-panelview-600-standard-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}