{"product_id":"allen-bradley-2711p-k10c4d1-panelview-plus-1000-operator-terminal","title":"Allen-Bradley 2711P-K10C4D1 PanelView Plus 1000 Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-K10C4D1 PanelView Plus 1000 Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-K10C4D1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711P-K10C4D1\u003c\/strong\u003e PanelView Plus 1000 Operator Terminal, provides keypad-based operator input, a 10.4 in color TFT LCD display, and Ethernet and RS-232 communications from an 18-32 VDC power source.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-K10C4D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 1000 Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSer A, B, C, D, and F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active matrix TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e211 x 158 mm (8.3 x 6.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eCCFL, 50,000 hours minimum life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad Rating\u003c\/td\u003e\n\u003ctd\u003e1 million presses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Keys\u003c\/td\u003e\n\u003ctd\u003eF1-F16, K1-K16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad Functions\u003c\/td\u003e\n\u003ctd\u003e0-9, special characters, Backspace, Enter, Left Tab, Right Tab, Shift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e32 MB Flash Memory \/ 32 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStated Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, USB, DH+, Remote I\/O, DH485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet and RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003e1761-NET-ENI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Color\u003c\/td\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFlash Memory and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-K10C4D1 contains 32 MB of Flash Memory and 32 MB of RAM, while the supplied specification also identifies 64 MB total memory. Firmware compatibility should be verified against the installed PanelView Plus 1000 hardware revision before applying firmware changes. The supplied data does not identify specific firmware revision limits.\u003c\/p\u003e\n\u003cp\u003eThe terminal provides Ethernet, RS-232, USB, DH+, Remote I\/O, and DH485 communication interfaces. The actual communication protocol and connected controller configuration must correspond to the selected physical port and installed system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input voltage is specified for the 2711P-K10C4D1?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify an input power range of 18-32 VDC, with an additional input voltage range entry of 18-30 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What type of operator input does the terminal provide?\u003c\/p\u003e\n\u003cp\u003eA: The terminal uses a physical keypad with F1-F16 and K1-K16 function keys, numeric keys, special-character keys, Backspace, Enter, Tab, and Shift functions. The specified keypad rating is 1 million presses.\u003c\/p\u003e\n\u003cp\u003eQ: Does the terminal support Ethernet and RS-232 communication?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Ethernet and RS-232 are explicitly listed as communication interfaces. The supplied data also lists DH+, Remote I\/O, DH485, and USB communication ports.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the available DC supply against the specified 18-32 VDC input range before energizing the terminal.\u003c\/li\u003e\n\u003cli\u003eUse wiring and overcurrent protection appropriate for the installed DC supply and control panel design.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring separately from high-current motor, contactor, and switching-power wiring where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eMaintain cable shielding and grounding practices consistent with the communication network and plant electrical design.\u003c\/li\u003e\n\u003cli\u003eConfirm connector orientation and mechanical retention before applying power.\u003c\/li\u003e\n\u003cli\u003eVerify the selected Ethernet, RS-232, USB, DH+, Remote I\/O, or DH485 interface against the controller and network configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck the installed terminal revision before firmware maintenance or application transfer.\u003c\/li\u003e\n\u003cli\u003eProvide adequate panel clearance for cable routing and connector access.\u003c\/li\u003e\n\u003cli\u003eDo not apply power until field wiring has been inspected for polarity, continuity, and accidental shorts.\u003c\/li\u003e\n\u003cli\u003eBecause the supplied documentation does not specify dimensions, operating temperature, or power consumption, use the applicable installation manual and nameplate data for these parameters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43838685085786,"sku":"2711P-K10C4D1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-K10C4D11.jpg?v=1786593692","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-k10c4d1-panelview-plus-1000-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}