Skip to content
Allen-Bradley 2711P-K12C4D8 PanelView Plus 6 1250 Operator Terminal

Allen-Bradley 2711P-K12C4D8 PanelView Plus 6 1250 Operator Terminal

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 2711P-K12C4D8

  • Condition: In stock

  • Product Type: PanelView Plus 6 1250 Operator Terminal

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 4536g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43838765989978,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2711P-K12C4D8","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 2711P-K12C4D8 PanelView Plus 6 1250 Operator Terminal","public_title":null,"options":["Default Title"],"price":12300,"weight":4536,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 2711P-K12C4D8 PanelView Plus 6 1250 Operator Terminal

Configured for keypad-based operator input and Ethernet/RS-232 communication in a PanelView Plus 6 system, the Allen-Bradley 2711P-K12C4D8 (2711P-K12C4D8 PanelView Plus 6 operator terminal) provides a 12.1 inch color TFT display, keypad interface, Ethernet, RS-232, and two USB peripheral ports from an 18-32 VDC supply.

Hardware Specifications

Parameter Specification
Model 2711P-K12C4D8
Brand Allen-Bradley
Product Type PanelView Plus 6 1250 Operator Terminal
Series PanelView Plus 6, Series A and Series B
Weight 10.00 lbs
Input Voltage 18-32 VDC
Display Size 12.1 inches
Display Type Color active-matrix TFT
Display Resolution 800 x 600 pixels
Display Color 18-bit color graphics
Display Area 246 x 184 mm
Backlight White LED, non-replaceable
Backlight Life 25,000 hours minimum at 25 deg C
Input Type Keypad
Keypad Rating 1 million presses
Function Keys F1-F20, K1-K20
Internal Flash Memory 512 MB
RAM 512 MB
Integrated Communication Ethernet, RS-232
USB Ports 2 USB peripheral ports
Communication Cable 2711-NC14
Operating System Windows CE 6
Lifecycle Status End of life

Firmware and Ethernet Interface Characteristics

The terminal provides integrated Ethernet and RS-232 communication interfaces with 512 MB Flash memory and 512 MB RAM. The supplied data identifies Ethernet connectivity but does not specify the supported Ethernet protocol, deterministic network performance, or application-level network timing. Firmware compatibility should therefore be verified against the installed PanelView Plus 6 software and terminal series before loading firmware or application files.

The 512 MB Flash memory provides non-volatile storage for the terminal operating environment and application data. The supplied specifications do not define firmware package versions, upgrade procedures, or cross-series firmware compatibility.

Frequently Asked Questions

Q: Is hot-swap operation specified for the 2711P-K12C4D8?
A: Hot-swap capability is not specified in the supplied technical data. The terminal should be treated as a powered-down installation unless the applicable manufacturer documentation explicitly permits live replacement.

Q: What supply voltage is required by the terminal?
A: The specified input voltage range is 18-32 VDC. The supplied data does not specify power consumption in watts or input current.

Q: Can the terminal communicate through both Ethernet and RS-232?
A: Yes. Ethernet and RS-232 are listed as integrated communication interfaces. Two USB peripheral ports are also provided.

Field Installation Guidelines

  • Verify the panel cutout and mechanical mounting requirements against the applicable PanelView Plus 6 installation documentation before installation.
  • Confirm that the external DC supply remains within the specified 18-32 VDC input range at the terminal terminals.
  • Route communication cables separately from high-voltage, high-current, and high-noise conductors where practical.
  • Use appropriate cable shielding and terminate shields according to the plant grounding and EMC design requirements.
  • Connect the Ethernet and RS-232 interfaces using cabling suitable for the selected communication network and installed environment.
  • Do not apply mechanical force to the display, keypad, USB connectors, or communication ports during installation.
  • Protect unused communication and peripheral ports from contamination where required by the installation environment.
  • Confirm terminal series, firmware requirements, application compatibility, and controller communication configuration before commissioning.
  • The supplied data identifies the lifecycle status as End of life; verify replacement and maintenance requirements before incorporating the terminal into a new installation.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured