{"product_id":"allen-bradley-2711p-k6c20d8-panelview-plus-6-operator-interface-terminal","title":"Allen-Bradley 2711P-K6C20D8 PanelView Plus 6 Operator Interface Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-K6C20D8 PanelView Plus 6 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for operator interface functions in PanelView Plus 6 systems, the \u003cstrong\u003eAllen-Bradley 2711P-K6C20D8\u003c\/strong\u003e (\u003cstrong\u003e2711P-K6C20D8\u003c\/strong\u003e PanelView Plus 6 Operator Interface Terminal) provides keypad input, a 5.7 in color display, Ethernet, RS-232, and USB communication interfaces from a DC-powered terminal.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-K6C20D8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries A and Series B Operator Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e256 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eNon-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003e2711-NC13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e884951344150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Communication Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-K6C20D8 provides Ethernet and RS-232 interfaces for terminal communication, with USB connectivity also identified in the supplied specifications. The Ethernet interface is available for network communication, while RS-232 provides serial connectivity. The supplied data does not specify supported Ethernet protocol variants, serial communication parameters, or network timing characteristics; these values should therefore be verified against the applicable PanelView Plus 6 documentation before system configuration.\u003c\/p\u003e\n\u003cp\u003eThe terminal operates from an 18-30 VDC input supply. The supplied data identifies the unit as DC-powered but does not provide a specific power-consumption value or backplane current requirement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the supplied specification confirm hot-swap operation for the 2711P-K6C20D8?\u003cbr\u003eA: No. The supplied data does not specify hot-swap capability. The terminal should be treated as a non-hot-swappable device unless the applicable installation documentation explicitly permits live replacement.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are identified for this terminal?\u003cbr\u003eA: Ethernet, RS-232, and USB are identified. The supplied data does not define the supported protocol set or detailed serial communication parameters.\u003c\/p\u003e\n\u003cp\u003eQ: Is the display backlight field-replaceable?\u003cbr\u003eA: No. The supplied specification identifies the backlight as non-replaceable.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 18-30 VDC supply voltage before connecting the terminal.\u003c\/li\u003e\n\u003cli\u003eInstall the terminal according to the specified PanelView Plus 6 enclosure and panel-cutout requirements.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between communication wiring and high-voltage or high-current conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet and RS-232 cables to minimize exposure to motor, contactor, and variable-frequency drive wiring.\u003c\/li\u003e\n\u003cli\u003eApply cable shielding and shield termination according to the selected communication cable and plant grounding standard.\u003c\/li\u003e\n\u003cli\u003eVerify connector seating and cable strain relief before applying power.\u003c\/li\u003e\n\u003cli\u003eDo not assume hot-swap capability unless it is explicitly permitted by the applicable Allen-Bradley installation documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm the installed terminal configuration and firmware compatibility before connecting it to an operating control network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43838841782362,"sku":"2711P-K6C20D8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-K6C20D81.jpg?v=1786605607","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-k6c20d8-panelview-plus-6-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}