{"id":43839562383450,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2711P-RAAT15","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 2711P-RAAT15 Auto-Reset Adapter Module","public_title":null,"options":["Default Title"],"price":12300,"weight":1361,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 2711P-RAAT15 Auto-Reset Adapter Module

Configured for automatic hardware reset execution in PanelView Plus 1500 and PanelView Plus CE 1500 terminals, the Allen-Bradley 2711P-RAAT15 (2711P-RAAT15 Auto-Reset Adapter Module) provides direct hardware-level reset functionality through the compatible terminal logic-module assembly.

Hardware Specifications

Parameter Specification
Model 2711P-RAAT15
Brand Allen-Bradley
Product Series PanelView Plus / PanelView Plus CE Accessories
Component Type Auto-Reset Adapter Module
Compatible Hardware PanelView Plus 1500; PanelView Plus CE 1500
Display Size 15.0-inch terminal
Reset Function Automatic hardware reset initiation
Interface / Integration Direct connection to the compatible logic module slot/chassis
Power Supply Powered directly via internal bus through the Logic Module
Operating Temp 0 deg C to 55 deg C
Storage Temp -25 deg C to 70 deg C
Relative Humidity 5% to 95%, non-condensing
Enclosure Rating Meets terminal rating when installed; NEMA 12, 13, 4X indoor
Certifications UL Listed, CE, C-Tick, RoHS Compliant

Logic Module and Backplane Integration

The 2711P-RAAT15 receives operating power through the internal bus associated with the compatible Logic Module rather than through a separately specified external power input. Its installation is therefore dependent on the physical and electrical configuration of the supported PanelView Plus terminal assembly.

The module is intended to initiate an automatic hardware reset when the terminal enters a recoverable fault condition or experiences a temporary power-related disturbance. Backplane communication characteristics and firmware flash compatibility should be verified against the installed terminal and Logic Module revision before replacement or system modification.

Frequently Asked Questions (FAQ)

Q: Does the 2711P-RAAT15 require a separate external power supply?
A: No separate external supply is specified. The module is powered through the internal bus via the Logic Module.

Q: Which terminals are specified as compatible with the 2711P-RAAT15?
A: The provided data specifies 15.0-inch PanelView Plus 1500 and PanelView Plus CE 1500 graphic display terminals.

Q: Is the 2711P-RAAT15 a standalone controller?
A: No. It is an Auto-Reset Adapter Module integrated into the compatible PanelView terminal assembly and logic-module interface.

Field Installation Guidelines

  • Verify that the installed terminal is a specified PanelView Plus 1500 or PanelView Plus CE 1500 configuration before installation.
  • Isolate terminal power before accessing the Logic Module or adapter-module interface.
  • Install the adapter only in the designated compatible slot or chassis interface.
  • Confirm that mating connectors are fully seated and mechanically secured before restoring power.
  • Keep signal and power wiring arranged according to the terminal installation requirements to limit exposure to electrical noise.
  • Where shielded wiring is used, terminate shields according to the applicable panel grounding and EMC practices.
  • Inspect the Logic Module interface for contamination, mechanical damage, or loose connections before installing the adapter.
  • Verify terminal firmware and Logic Module compatibility against the applicable hardware documentation before commissioning.
  • Restore power only after the terminal assembly has been correctly reassembled and all electrical connections have been inspected.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products