{"product_id":"allen-bradley-2711p-rn15s-controlnet-communication-adapter","title":"Allen-Bradley 2711P-RN15S ControlNet Communication Adapter","description":"\u003ch2\u003eAllen-Bradley 2711P-RN15S ControlNet Communication Adapter\u003c\/h2\u003e\n\u003cp\u003eConfigured for ControlNet communication in PanelView Plus and PanelView Plus CE operator terminals, the \u003cstrong\u003eAllen-Bradley 2711P-RN15S\u003c\/strong\u003e (\u003cstrong\u003e2711P-RN15S\u003c\/strong\u003e ControlNet communication adapter) provides two ControlNet communication channels and one RJ45 Network Access Port (NAP) for scheduled and unscheduled messaging.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-RN15S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControlNet communication adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus \/ PanelView Plus CE Operator Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlNet Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Access Port (NAP)\u003c\/td\u003e\n\u003ctd\u003e1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Messages\u003c\/td\u003e\n\u003ctd\u003eScheduled and unscheduled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlNet Media\u003c\/td\u003e\n\u003ctd\u003e1786-RG6\/A, 1786-RG6F\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlNet Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Nodes\u003c\/td\u003e\n\u003ctd\u003e1-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNAP Cable\u003c\/td\u003e\n\u003ctd\u003e1786-CP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.19 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetaining Screw\u003c\/td\u003e\n\u003ctd\u003eM3 metric screw, 5 mm long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e781180181474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e43201404 - Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControlNet Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RN15S provides two ControlNet channels for connection to the ControlNet network associated with compatible PanelView Plus terminals. The adapter supports both scheduled and unscheduled messages and supports ControlNet redundancy.\u003c\/p\u003e\n\u003cp\u003eThe network interface supports ControlNet media types 1786-RG6\/A and 1786-RG6F\/B. The RJ45 NAP provides local Network Access Port connectivity using the specified 1786-CP cable. The documented node range is 1-99.\u003c\/p\u003e\n\u003cp\u003eThe module is specified for PanelView Plus 700-1500 applications and is compatible with PanelView Plus and PanelView Plus CE operator terminals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 2711P-RN15S be removed or inserted while the terminal is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Removal and insertion under power is not supported for this module.\u003c\/p\u003e\n\u003cp\u003eQ: How many ControlNet channels and Network Access Ports are provided?\u003c\/p\u003e\n\u003cp\u003eA: The module provides two ControlNet communication channels and one RJ45 Network Access Port.\u003c\/p\u003e\n\u003cp\u003eQ: Which ControlNet media are specified for this adapter?\u003c\/p\u003e\n\u003cp\u003eA: The supplied technical data specifies 1786-RG6\/A and 1786-RG6F\/B ControlNet media. The NAP cable is specified as 1786-CP.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the adapter only in a compatible PanelView Plus or PanelView Plus CE terminal configuration.\u003c\/li\u003e\n\u003cli\u003eRemove system power before installing or removing the module because hot insertion is not supported.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the specified M3 metric screw, 5 mm long.\u003c\/li\u003e\n\u003cli\u003eRoute ControlNet cabling separately from high-voltage power conductors and high-current switching wiring where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain the shielding and cable termination practices specified for the installed ControlNet media.\u003c\/li\u003e\n\u003cli\u003eUse the specified 1786-CP cable for the Network Access Port connection.\u003c\/li\u003e\n\u003cli\u003eVerify the ControlNet channel assignment and network topology before applying power.\u003c\/li\u003e\n\u003cli\u003eInspect connectors and cable routing for mechanical strain, excessive bending, or damage before commissioning.\u003c\/li\u003e\n\u003cli\u003eDo not infer operating temperature, power consumption, or dimensional limits from the supplied data; verify these values against the applicable Allen-Bradley technical documentation before installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43846203572314,"sku":"2711P-RN15S","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-RN15S2.jpg?v=1786687800","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-rn15s-controlnet-communication-adapter","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}