{"product_id":"allen-bradley-2711p-rp2-panelview-plus-standard-logic-module","title":"Allen-Bradley 2711P-RP2 PanelView Plus Standard Logic Module","description":"\u003ch2\u003eAllen-Bradley 2711P-RP2 PanelView Plus Standard Logic Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for memory processing and application execution in PanelView Plus 700 to 1500 terminals, the \u003cstrong\u003eAllen-Bradley 2711P-RP2\u003c\/strong\u003e (\u003cstrong\u003e2711P-RP2\u003c\/strong\u003e Standard Logic Module) provides 128 MB flash memory and 128 MB RAM with a 24 VDC input supply.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-RP2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eStandard Logic Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminals\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 700 to 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Support\u003c\/td\u003e\n\u003ctd\u003eSingle Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewPoint Compatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Type\u003c\/td\u003e\n\u003ctd\u003eDC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Shock\u003c\/td\u003e\n\u003ctd\u003e15 G for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Non-Operating Shock\u003c\/td\u003e\n\u003ctd\u003e30 G for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Types\u003c\/td\u003e\n\u003ctd\u003eFlash and RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView Plus Memory and Power Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RP2 provides separate 128 MB flash and 128 MB RAM resources for PanelView Plus terminal operation. The module is specified for 24 VDC nominal input, with an 18-30 VDC input range and a stated 70 W power consumption.\u003c\/p\u003e\n\u003cp\u003eThe supplied compatibility data identifies PanelView Plus 700 through 1500 terminals. ViewPoint compatibility is also specified for the module.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What memory configuration is provided by the 2711P-RP2?\u003cbr\u003eA: The module provides 128 MB of flash memory and 128 MB of RAM.\u003c\/p\u003e\n\u003cp\u003eQ: What DC supply is specified for the 2711P-RP2?\u003cbr\u003eA: The specified nominal input is 24 VDC, with an input range of 18-30 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Which PanelView Plus terminals are identified as compatible?\u003cbr\u003eA: The supplied technical data identifies PanelView Plus 700 through 1500 terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the terminal model against the specified PanelView Plus 700 to 1500 compatibility range before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the available DC supply remains within the specified 18-30 VDC input range.\u003c\/li\u003e\n\u003cli\u003eUse wiring and overcurrent protection appropriate for the stated 70 W power consumption.\u003c\/li\u003e\n\u003cli\u003eDe-energize the terminal before installing or removing the logic module unless the applicable Allen-Bradley installation documentation explicitly permits the operation under a defined hot-swap procedure.\u003c\/li\u003e\n\u003cli\u003eRoute DC supply wiring separately from high-energy switching conductors and sources of significant electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper protective grounding and follow the PanelView Plus installation documentation for chassis and cable shield termination.\u003c\/li\u003e\n\u003cli\u003eVerify connector seating and mechanical retention before applying power.\u003c\/li\u003e\n\u003cli\u003eOperate the assembly within the specified 0 to 55 deg C temperature range and 5 to 95% non-condensing relative humidity range.\u003c\/li\u003e\n\u003cli\u003eAvoid installation locations exceeding the specified 2000 m operating altitude unless the applicable equipment documentation provides a derating requirement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43846314098778,"sku":"2711P-RP2","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-RP22.jpg?v=1786689095","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-rp2-panelview-plus-standard-logic-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}