{"product_id":"allen-bradley-2711p-rp8a-panelview-plus-6-logic-module","title":"Allen-Bradley 2711P-RP8A PanelView Plus 6 Logic Module","description":"\u003ch2\u003eAllen-Bradley 2711P-RP8A PanelView Plus 6 Logic Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for processing and interface management in PanelView Plus 6 terminals, the \u003cstrong\u003eAllen-Bradley 2711P-RP8A\u003c\/strong\u003e (\u003cstrong\u003e2711P-RP8A PanelView Plus 6 Logic Module\u003c\/strong\u003e) provides the processing hardware, system memory, power supply, real-time clock, and communication interfaces required for FactoryTalk View Machine Edition runtime execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-RP8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6, 700 to 1500 terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eLogic Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC, 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e160 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1.3 to 0.65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB Flash, approximately 79 MB available for user application storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows CE 6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ-45 Ethernet port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Host\u003c\/td\u003e\n\u003ctd\u003e2 x USB 2.0 Host ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Device\u003c\/td\u003e\n\u003ctd\u003e1 x USB Mini-B Device port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompactFlash\u003c\/td\u003e\n\u003ctd\u003e1 x Type I CompactFlash slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card\u003c\/td\u003e\n\u003ctd\u003e1 x SD Card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Communication Modules\u003c\/td\u003e\n\u003ctd\u003eDH-485, ControlNet, DeviceNet, DH+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware and Flash Memory Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RP8A contains 512 MB of non-volatile Flash memory and operates with Windows CE 6.0. The available Flash capacity includes approximately 79 MB for user application storage. Firmware or runtime updates should be verified against the specific PanelView Plus 6 terminal configuration before installation to maintain compatibility between the logic module, operating environment, and FactoryTalk View ME runtime.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What input power does the 2711P-RP8A require?\u003cbr\u003eA: The module accepts 85 to 264 VAC at 47 to 63 Hz and has a maximum power consumption of 160 VA.\u003c\/p\u003e\n\u003cp\u003eQ: Which physical communication interfaces are provided?\u003cbr\u003eA: The module provides one 10\/100 Mbps RJ-45 Ethernet port, one RS-232 serial port, two USB 2.0 Host ports, and one USB Mini-B Device port.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module use removable storage media?\u003cbr\u003eA: Yes. The hardware provides one Type I CompactFlash slot and one SD Card slot. The supplied data also identifies approximately 79 MB of Flash memory as available for user application storage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the PanelView Plus 6 terminal configuration is compatible with the 2711P-RP8A logic module before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the available AC supply is within the specified 85 to 264 VAC range and frequency range before energizing the module.\u003c\/li\u003e\n\u003cli\u003eDe-energize the terminal before removing or installing the logic module or accessing internal interfaces.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet, RS-232, USB, and other communication wiring separately from high-voltage power conductors where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shield termination and grounding practices for installed communication cables according to the applicable cable and system installation requirements.\u003c\/li\u003e\n\u003cli\u003eProvide sufficient enclosure clearance for connector access and module removal; the supplied data does not specify a dimensional clearance requirement.\u003c\/li\u003e\n\u003cli\u003eDo not install the module outside the specified 0 deg C to 55 deg C operating temperature or 5% to 95% non-condensing relative humidity range.\u003c\/li\u003e\n\u003cli\u003eVerify CompactFlash and SD card installation orientation and ensure removable media is securely seated before operation.\u003c\/li\u003e\n\u003cli\u003eConfirm optional DH-485, ControlNet, DeviceNet, or DH+ communication hardware compatibility before installing an expansion communication module.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43846283493466,"sku":"2711P-RP8A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-RP8A2.jpg?v=1786688440","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-rp8a-panelview-plus-6-logic-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}