{"product_id":"allen-bradley-2711p-t10c4a1-panelview-plus-1000-operator-interface-terminal","title":"Allen-Bradley 2711P-T10C4A1 PanelView Plus 1000 Operator Interface Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-T10C4A1 PanelView Plus 1000 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen operator interaction in the PanelView Plus 1000 platform, the \u003cstrong\u003eAllen-Bradley 2711P-T10C4A1\u003c\/strong\u003e (\u003cstrong\u003e2711P-T10C4A1\u003c\/strong\u003e operator interface terminal) provides direct graphical display and physical communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T10C4A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Range\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet and RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e2711P-RL10C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003e1761-NET-ENI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Revisions\u003c\/td\u003e\n\u003ctd\u003eSer A, B, C, D, and F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView Plus Communication and Firmware Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T10C4A1 provides Ethernet and RS-232 interfaces for connection with external automation equipment and serial devices. Communication wiring shall follow the electrical requirements of the connected equipment and interface type.\u003c\/p\u003e\n\u003cp\u003eThe terminal incorporates a 10.4 in color touchscreen with 640 x 480 pixel resolution. The touchscreen provides direct operator input through the graphical display assembly.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies 64 MB of memory and two USB ports. Firmware flash compatibility shall be verified against the installed PanelView Plus hardware series and revision before applying firmware changes.\u003c\/p\u003e\n\u003cp\u003eThe specified backlight assembly is 2711P-RL10C2. Replacement or servicing should maintain connector compatibility and the electrical characteristics specified for the terminal assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input voltage does the 2711P-T10C4A1 accept?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify an input range of 85-264 VAC, with 100-240 VAC also listed.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are provided?\u003c\/p\u003e\n\u003cp\u003eA: The terminal provides Ethernet and RS-232 communication interfaces, plus two USB ports.\u003c\/p\u003e\n\u003cp\u003eQ: What display hardware is installed?\u003c\/p\u003e\n\u003cp\u003eA: The terminal uses a 10.4 in color touchscreen with a resolution of 640 x 480 pixels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the terminal model and series revision before installation or firmware service.\u003c\/li\u003e\n\u003cli\u003eConfirm the supplied AC voltage remains within the specified 85-264 VAC input range.\u003c\/li\u003e\n\u003cli\u003eRoute AC power wiring separately from low-level communication and signal wiring where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate separation between communication cables and high-current switching conductors.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cable where required by the connected network or site wiring standard.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the plant grounding scheme and avoid unintended ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet and RS-232 connector assignments before energizing connected equipment.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal mechanically according to the PanelView Plus installation requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm touchscreen operation after mounting without applying excessive mechanical pressure to the display.\u003c\/li\u003e\n\u003cli\u003eVerify USB connections before commissioning any attached peripheral equipment.\u003c\/li\u003e\n\u003cli\u003eCheck firmware compatibility against the installed hardware series before performing firmware updates.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43856059695194,"sku":"2711P-T10C4A1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-T10C4A12.jpg?v=1786949856","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-t10c4a1-panelview-plus-1000-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}