{"product_id":"allen-bradley-2711p-t10c4d6-panelview-plus-1000-terminal","title":"Allen-Bradley 2711P-T10C4D6 PanelView Plus 1000 Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-T10C4D6 PanelView Plus 1000 Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen HMI operation in the PanelView Plus 1000 platform, the \u003cstrong\u003eAllen-Bradley 2711P-T10C4D6\u003c\/strong\u003e (\u003cstrong\u003e2711P-T10C4D6\u003c\/strong\u003e PanelView Plus terminal) provides color graphical display and Ethernet or RS-232 communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T10C4D6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003ePanelView terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor graphics touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e2711P-RL10C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003e1761-NET-ENI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSer A, B, C, D, and F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598349265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView Plus Communication and Hardware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T10C4D6 provides Ethernet and RS-232 interfaces for external communication connections. Two USB ports are also provided for compatible peripheral or service connections.\u003c\/p\u003e\n\u003cp\u003eThe terminal uses a 10.4 in. color touchscreen for operator input and graphical process visualization. Its specified DC input range is 18-32 VDC.\u003c\/p\u003e\n\u003cp\u003eAs an Allen-Bradley PanelView Plus 1000 terminal, communication and application compatibility depend on the installed terminal configuration and supported firmware environment. The supplied data does not specify firmware revision requirements or Ethernet protocol details.\u003c\/p\u003e\n\u003cp\u003eThe listed 2711P-RL10C2 backlight is associated with the display assembly. The 1761-NET-ENI is identified as the specified communication cable in the supplied data.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What DC supply voltage does the 2711P-T10C4D6 require?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specification identifies an input power range of 18-32 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Which physical communication interfaces are available?\u003c\/p\u003e\n\u003cp\u003eA: The terminal provides Ethernet, RS-232, and two USB ports according to the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eQ: Does the supplied data define hot-swap or firmware upgrade behavior?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied information does not specify hot-swap limits, firmware compatibility, or upgrade procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the terminal model and installed hardware configuration before panel installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the available DC supply remains within the specified 18-32 VDC input range.\u003c\/li\u003e\n\u003cli\u003eUse wiring practices appropriate for low-voltage industrial DC control equipment.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables separately from high-current power conductors and sources of significant electrical noise.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate separation between Ethernet or RS-232 communication wiring and switching power circuits.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the grounding design of the installed control system.\u003c\/li\u003e\n\u003cli\u003eAvoid creating unintended ground loops when connecting shielded communication cables.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal mechanically before connecting field wiring or communication cables.\u003c\/li\u003e\n\u003cli\u003eInspect USB, Ethernet, and RS-232 connectors for correct orientation and mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eDo not apply or remove wiring while energized unless the applicable installation procedure explicitly permits it.\u003c\/li\u003e\n\u003cli\u003eVerify polarity and DC supply wiring before energizing the terminal.\u003c\/li\u003e\n\u003cli\u003eConfirm the installed backlight assembly against the specified 2711P-RL10C2 component identification.\u003c\/li\u003e\n\u003cli\u003eApply the applicable PanelView Plus installation and electrical clearance requirements for the actual enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43856130605146,"sku":"2711P-T10C4D6","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-T10C4D62.jpg?v=1786951169","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-t10c4d6-panelview-plus-1000-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}