{"product_id":"allen-bradley-2711p-t12c4d2-panelview-plus-1250-operator-terminal","title":"Allen-Bradley 2711P-T12C4D2 PanelView Plus 1250 Operator Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-T12C4D2 PanelView Plus 1250 Operator Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touch-based operator input and Ethernet or serial communication in PanelView Plus systems, the \u003cstrong\u003eAllen-Bradley 2711P-T12C4D2\u003c\/strong\u003e (\u003cstrong\u003e2711P-T12C4D2\u003c\/strong\u003e operator terminal) provides direct HMI display and control functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T12C4D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.01 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active matrix TFT LCD with CCF backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e12.1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e246 x 184 mm (9.7 x 7.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e800 x 600 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Interface\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Force\u003c\/td\u003e\n\u003ctd\u003e10 to 110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuating Lifespan\u003c\/td\u003e\n\u003ctd\u003e1 million presses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Module\u003c\/td\u003e\n\u003ctd\u003e128 MB RAM; 128 MB non-volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 Ethernet, 1 RS-232, 2 USB host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eSerial or Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W maximum; 39 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e2.9 A maximum at 24 VDC; 1.6 A typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area Resolution\u003c\/td\u003e\n\u003ctd\u003e800 x 600 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662073072201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial HMI Communication and Control Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T12C4D2 provides an 800 x 600 pixel operator display with an analog resistive touch interface. The touch interface specifies an operating force of 10 to 110 g and an actuating lifespan of 1 million presses.\u003c\/p\u003e\n\u003cp\u003eEthernet and RS-232 interfaces support network or serial communication, while two USB host ports provide peripheral connectivity. The supplied logic module contains 128 MB RAM and 128 MB non-volatile memory.\u003c\/p\u003e\n\u003cp\u003eThe 18-32 VDC input range requires a suitable regulated DC supply. Maximum power consumption is specified as 70 W, corresponding to 2.9 A at 24 VDC. Typical consumption is 39 W, corresponding to 1.6 A at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eFor Allen-Bradley controller integration, Ethernet wiring should remain separated from high-current power conductors and high-noise switching circuits. Shield termination and grounding should follow the applicable PanelView Plus installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What display and touch technology does the 2711P-T12C4D2 use?\u003c\/p\u003e\n\u003cp\u003eA: The terminal uses a 12.1 in color TFT LCD with 800 x 600 resolution and analog resistive touch input.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply does the terminal require?\u003c\/p\u003e\n\u003cp\u003eA: The specified input range is 18-32 VDC, with 70 W maximum and 39 W typical power consumption.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are provided?\u003c\/p\u003e\n\u003cp\u003eA: The terminal provides one Ethernet port, one RS-232 interface, and two USB host ports.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal in a panel opening that meets the mechanical requirements specified for the PanelView Plus 1250 enclosure.\u003c\/p\u003e\n\u003cp\u003eVerify the DC supply polarity and voltage before connecting the power terminals. Do not apply AC voltage to the DC input.\u003c\/p\u003e\n\u003cp\u003eUse appropriately rated conductors for the maximum specified current and install overcurrent protection according to the control panel design.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet, RS-232, and USB cabling away from motor leads, contactor wiring, variable-frequency drive outputs, and other high-noise conductors.\u003c\/p\u003e\n\u003cp\u003eWhere shielded communication cable is required, terminate the shield according to the applicable Allen-Bradley installation documentation and the plant grounding scheme.\u003c\/p\u003e\n\u003cp\u003eProvide adequate clearance around the terminal for cable routing, connector access, heat dissipation, and service operations.\u003c\/p\u003e\n\u003cp\u003eDo not assume hot-swap capability unless the applicable PanelView Plus hardware documentation explicitly permits removal or connection while energized.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify display operation, touch response, Ethernet connectivity, serial communication, USB operation, and controller data exchange.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43856231759962,"sku":"2711P-T12C4D2","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-T12C4D22.jpg?v=1786952949","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-t12c4d2-panelview-plus-1250-operator-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}