{"product_id":"allen-bradley-2711p-t12c4d9-panelview-plus-6-operator-interface-terminal","title":"Allen-Bradley 2711P-T12C4D9 PanelView Plus 6 Operator Interface Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-T12C4D9 PanelView Plus 6 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for operator visualization and touch-based machine control in PanelView Plus 6 systems, the \u003cstrong\u003eAllen-Bradley 2711P-T12C4D9\u003c\/strong\u003e (\u003cstrong\u003e2711P-T12\u003c\/strong\u003e PanelView Plus 6 operator interface terminal) provides direct display, input, and communication functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T12C4D9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6, 1200 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e12.1 in diagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active-matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e800 x 600 SVGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Depth\u003c\/td\u003e\n\u003ctd\u003e18-bit color graphics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Interface\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eMicrosoft Windows CE 6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime Software\u003c\/td\u003e\n\u003ctd\u003eFactoryTalk View Machine Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 32 VDC, 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W maximum, 2.9 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM, 512 MB non-volatile flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x Ethernet, 10\/100 Mbps, RJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232 \/ DH-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Host Ports\u003c\/td\u003e\n\u003ctd\u003e2 x USB 2.0 Host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Device Port\u003c\/td\u003e\n\u003ctd\u003e1 x USB Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Expansion\u003c\/td\u003e\n\u003ctd\u003eSD card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and HMI Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T12C4D9 uses a 12.1 in color TFT display with 800 x 600 SVGA resolution for runtime visualization.\u003c\/p\u003e\n\u003cp\u003eThe analog resistive touch interface provides direct operator input without requiring an external pointing device.\u003c\/p\u003e\n\u003cp\u003eThe terminal operates with Microsoft Windows CE 6.0 and FactoryTalk View Machine Edition runtime software.\u003c\/p\u003e\n\u003cp\u003eEthernet communication uses a 10\/100 Mbps RJ-45 interface for network-connected control and visualization functions.\u003c\/p\u003e\n\u003cp\u003eThe RS-232 \/ DH-485 interface supports serial communication within compatible Allen-Bradley control architectures.\u003c\/p\u003e\n\u003cp\u003eTwo USB 2.0 Host ports and one USB Device port provide peripheral and service connectivity.\u003c\/p\u003e\n\u003cp\u003eThe 18 to 32 VDC input range is specified for a 24 VDC nominal supply connection.\u003c\/p\u003e\n\u003cp\u003eThe maximum stated power consumption is 70 W, corresponding to 2.9 A at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eInternal storage consists of 512 MB RAM and 512 MB non-volatile flash memory, with additional SD card storage capability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What input voltage does the 2711P-T12C4D9 require?\u003cbr\u003eA: The terminal accepts 18 to 32 VDC, with 24 VDC specified as the nominal input voltage.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are provided on this terminal?\u003cbr\u003eA: The hardware provides Ethernet at 10\/100 Mbps, RS-232 \/ DH-485, two USB 2.0 Host ports, and one USB Device port.\u003c\/p\u003e\n\u003cp\u003eQ: What type of touch technology is used?\u003cbr\u003eA: The 12.1 in display uses an analog resistive touch screen for operator input.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the terminal in a panel cutout compatible with the specified 12.1 in operator interface assembly.\u003c\/p\u003e\n\u003cp\u003eVerify the supplied DC voltage remains within the specified 18 to 32 VDC input range during operation.\u003c\/p\u003e\n\u003cp\u003eUse appropriately sized conductors for the DC supply and protect the circuit according to the installation design.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet, serial, USB, and power wiring separately where practical to reduce conducted electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain suitable clearance around connectors and service-access areas before securing the terminal in the enclosure.\u003c\/p\u003e\n\u003cp\u003eConnect cable shields according to the plant grounding architecture and avoid creating unintended shield ground loops.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cabling where required by the connected network and maintain controlled cable routing near high-current conductors.\u003c\/p\u003e\n\u003cp\u003eVerify the touch surface remains accessible and unobstructed after panel installation.\u003c\/p\u003e\n\u003cp\u003eBefore applying power, inspect connector seating, supply polarity, grounding, and cable termination.\u003c\/p\u003e\n\u003cp\u003eConfirm the configured FactoryTalk View Machine Edition application matches the terminal hardware and installed runtime environment.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43856240541786,"sku":"2711P-T12C4D9","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-T12C4D92.jpg?v=1786953293","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-t12c4d9-panelview-plus-6-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}