{"product_id":"allen-bradley-2711p-t6m20d-panelview-plus-600-operator-interface-terminal","title":"Allen Bradley 2711P-T6M20D PanelView Plus 600 Operator Interface Terminal","description":"\u003ch2\u003eAllen Bradley 2711P-T6M20D PanelView Plus 600 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen operator interaction in PanelView Plus 600 systems, the \u003cstrong\u003eAllen Bradley 2711P-T6M20D\u003c\/strong\u003e (\u003cstrong\u003e2711P-T6M20D\u003c\/strong\u003e Operator Interface Terminal) provides direct graphical control through a 5.5 in grayscale FSTN display, resistive touch input, Ethernet, RS-232, and USB interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T6M20D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W max; 1.0 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC input; nominal 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGrayscale passive matrix, film compensated super-twist nematic (FSTN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e112 x 84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Interface\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Force\u003c\/td\u003e\n\u003ctd\u003e10-110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuating Lifespan\u003c\/td\u003e\n\u003ctd\u003e1 million presses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Input\u003c\/td\u003e\n\u003ctd\u003eTouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 Ethernet, 1 RS-232, 2 USB host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Memory\u003c\/td\u003e\n\u003ctd\u003eSeries A: 5 MB; Series B: 10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus Graphic Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e781180130243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAllen Bradley PanelView Plus Communication and HMI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T6M20D combines graphical display processing with local touchscreen input for operator interface functions. Its analog resistive touch interface accepts physical contact across the configured display area.\u003c\/p\u003e\n\u003cp\u003eEthernet provides network communication, while RS-232 supports serial device connections. Two USB host ports provide local peripheral connectivity where supported by the terminal configuration.\u003c\/p\u003e\n\u003cp\u003eThe supplied specifications identify Series A and Series B memory variants. Therefore, terminal memory capacity should be verified against the installed hardware series before application deployment or firmware-related maintenance.\u003c\/p\u003e\n\u003cp\u003eThe grayscale FSTN display provides 320 x 240 pixel resolution over a stated 112 x 84 mm active display area. The specified maximum power consumption is 25 W at a 24 VDC supply condition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What DC supply range is specified for the 2711P-T6M20D?\u003c\/p\u003e\n\u003cp\u003eA: The terminal accepts an external supply from 18-30 VDC, with 24 VDC identified as the nominal supply.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are provided on the terminal?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data specifies 1 Ethernet port, 1 RS-232 port, and 2 USB host ports.\u003c\/p\u003e\n\u003cp\u003eQ: Does the terminal use a resistive or capacitive touchscreen?\u003c\/p\u003e\n\u003cp\u003eA: The specified touch interface is analog resistive, with an operating force of 10-110 g and a stated lifespan of 1 million presses.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal in a panel cutout that matches the mechanical dimensions specified by the applicable Allen Bradley installation documentation.\u003c\/p\u003e\n\u003cp\u003eProvide a regulated DC supply within the specified 18-30 VDC input range and observe the required wiring polarity.\u003c\/p\u003e\n\u003cp\u003eSeparate DC power wiring from high-current switching conductors, motor cables, and other sources of conducted or radiated electrical noise.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet and RS-232 communication cables separately from power conductors where practical, particularly around contactors, drives, and switching loads.\u003c\/p\u003e\n\u003cp\u003eTerminate communication cable shields according to the system grounding design and the applicable Allen Bradley installation requirements.\u003c\/p\u003e\n\u003cp\u003eUse the Ethernet connection only with network equipment and cabling compatible with the configured PanelView Plus 600 communication architecture.\u003c\/p\u003e\n\u003cp\u003eDo not assume hot-swap capability for field replacement unless the applicable hardware and installation documentation explicitly permits energized removal or insertion.\u003c\/p\u003e\n\u003cp\u003eVerify the terminal hardware series before loading application files or firmware because the supplied data identifies different memory capacities for Series A and Series B hardware.\u003c\/p\u003e\n\u003cp\u003eConfirm display operation, touchscreen response, Ethernet communication, RS-232 communication, and USB device operation after installation and before placing the terminal into service.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43860691714138,"sku":"2711P-T6M20D","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-T6M20D2.jpg?v=1787038029","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-t6m20d-panelview-plus-600-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}