{"product_id":"allen-bradley-2711p-t7c4a8-panelview-plus-6-700-graphic-terminal","title":"Allen-Bradley 2711P-T7C4A8 PanelView Plus 6 700 Graphic Terminal","description":"\u003ch2\u003eAllen-Bradley 2711P-T7C4A8 PanelView Plus 6 700 Graphic Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen operator interaction in PanelView Plus 6 systems, the \u003cstrong\u003eAllen-Bradley 2711P-T7C4A8\u003c\/strong\u003e (\u003cstrong\u003e2711P-T7C4A8\u003c\/strong\u003e PanelView Plus 6 700 Graphic Terminal) provides direct visual monitoring and control through a 6.5-inch VGA display, Ethernet, RS-232, and USB interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T7C4A8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6, 700 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6 700 Graphic Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6.5-inch color TFT transflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels, VGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Depth\u003c\/td\u003e\n\u003ctd\u003e18-bit color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Input\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC, 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e1 port, 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Host\u003c\/td\u003e\n\u003ctd\u003e2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Device\u003c\/td\u003e\n\u003ctd\u003e1 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM, 512 MB non-volatile flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003eApproximately 79 MB non-volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows CE 6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 12, NEMA 13, NEMA 4X indoor use, IP54, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Model\u003c\/td\u003e\n\u003ctd\u003e2711P-T7C22A9P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView Plus 6 Communication and Firmware Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T7C4A8 provides Ethernet communication at 10\/100 Mbps for supported industrial network data exchange. The RS-232 interface supports serial device communication where the application requires a physical serial connection.\u003c\/p\u003e\n\u003cp\u003eTwo USB Host ports and one USB Device port provide additional peripheral and service interfaces. Port assignment should follow the terminal hardware documentation and application requirements.\u003c\/p\u003e\n\u003cp\u003eThe terminal contains 512 MB of RAM and 512 MB of non-volatile flash memory. Approximately 79 MB of non-volatile memory is allocated for user application storage according to the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eWindows CE 6.0 defines the operating system environment. Therefore, application deployment and firmware compatibility should be verified against the installed PanelView Plus 6 software and terminal revision before field replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What display and touch hardware does the 2711P-T7C4A8 use?\u003c\/p\u003e\n\u003cp\u003eA: It uses a 6.5-inch color TFT transflective display with 640 x 480 VGA resolution and analog resistive touch input.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply does the terminal require?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specification lists 85 to 264 VAC at 47 to 63 Hz, with maximum consumption of 60 VA.\u003c\/p\u003e\n\u003cp\u003eQ: Can the terminal communicate through both Ethernet and serial interfaces?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware provides one 10\/100 Mbps Ethernet port and one RS-232 communication port.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal in a panel cutout that mechanically supports the specified enclosure configuration and maintains adequate service access.\u003c\/p\u003e\n\u003cp\u003eVerify the incoming AC supply before energizing the terminal. Protect the circuit according to applicable electrical installation standards and the equipment documentation.\u003c\/p\u003e\n\u003cp\u003eRoute AC power wiring separately from low-level communication and signal wiring where practical. Avoid parallel routing with high-current motor, contactor, or variable-frequency drive conductors.\u003c\/p\u003e\n\u003cp\u003eFor Ethernet connections, use suitable industrial-grade cabling and maintain separation from high-noise power conductors. Confirm connector seating before commissioning network communication.\u003c\/p\u003e\n\u003cp\u003eFor RS-232 wiring, observe the applicable signal pin assignment and cable length limitations defined by the connected equipment.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the plant grounding design and equipment documentation. Avoid creating unintended ground loops through multiple shield termination points.\u003c\/p\u003e\n\u003cp\u003eMaintain the specified 0 to 55 deg C operating environment during continuous operation. Do not obstruct the terminal enclosure or installation area with wiring, mounting hardware, or other equipment.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied documentation identifies 2711P-T7C22A9P as the replacement model, verify application compatibility, terminal configuration, firmware requirements, and stored application migration requirements before replacement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43861635432538,"sku":"2711P-T7C4A8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711P-T7C4A82.jpg?v=1787041404","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711p-t7c4a8-panelview-plus-6-700-graphic-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}