{"product_id":"allen-bradley-2711pc-t6c20d-panelview-plus-6-compact-terminal","title":"Allen-Bradley 2711PC-T6C20D PanelView Plus 6 Compact Terminal","description":"\u003ch2\u003eAllen-Bradley 2711PC-T6C20D PanelView Plus 6 Compact Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen operator interaction in a PanelView Plus 6 Compact system, the \u003cstrong\u003eAllen-Bradley 2711PC-T6C20D\u003c\/strong\u003e (\u003cstrong\u003e2711PC-T6C20D\u003c\/strong\u003e PanelView Plus 6 Compact Terminal) provides a 5.7 in color TFT display, analog resistive touch input, and Ethernet, RS-232, and USB communication interfaces. The terminal operates from 18...30 VDC with 24 VDC nominal input.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711PC-T6C20D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6 Compact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 6 Compact Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W max; 9 W typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18...30 VDC; 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active-matrix TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e115 x 86 mm (4.5 x 3.4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Depth\u003c\/td\u003e\n\u003ctd\u003e18-bit color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuminance\u003c\/td\u003e\n\u003ctd\u003e440 cd\/m2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eWhite LED, non-replaceable; 25,000 h minimum at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Interface\u003c\/td\u003e\n\u003ctd\u003e4-wire analog resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Actuation\u003c\/td\u003e\n\u003ctd\u003e1 million presses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Operating Force\u003c\/td\u003e\n\u003ctd\u003e10...110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree User Memory\u003c\/td\u003e\n\u003ctd\u003eApprox. 73 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, 1 USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eBattery-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTC Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2 minutes\/month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTC Battery\u003c\/td\u003e\n\u003ctd\u003eField-replaceable CR2032 type or Allen-Bradley 2711P-RY2032 equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA\/UL Type 12, 13, 4X indoor use only; IEC IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows CE 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Messages\u003c\/td\u003e\n\u003ctd\u003eUp to 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Screens\u003c\/td\u003e\n\u003ctd\u003eUp to 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe terminal provides Ethernet, RS-232, and USB interfaces for operator-interface communications and service functions. Ethernet cabling should be routed separately from high-current switching conductors and variable-frequency drive output wiring where practical to reduce conducted and radiated interference.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility should be checked against the exact PanelView Plus 6 Compact terminal series, catalog number, and installed firmware revision before an update is performed. Firmware packages intended for a different terminal family or hardware revision should not be applied without documented compatibility.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies Ethernet capability but does not specify an EtherNet\/IP revision, network speed, firmware revision, or deterministic communication timing. These values should therefore be taken from the applicable Allen-Bradley technical manual for the installed terminal.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What DC supply range is specified for the 2711PC-T6C20D?\u003c\/p\u003e\n\u003cp\u003eA: The specified input range is 18...30 VDC, with 24 VDC nominal input. The supplied data requires a Class 2, SELV, or PELV power supply.\u003c\/p\u003e\n\u003cp\u003eQ: What touch technology is used?\u003c\/p\u003e\n\u003cp\u003eA: The terminal uses a 4-wire analog resistive touchscreen with a specified actuation life of 1 million presses and an operating force of 10...110 g.\u003c\/p\u003e\n\u003cp\u003eQ: Can firmware be upgraded using any PanelView Plus firmware package?\u003c\/p\u003e\n\u003cp\u003eA: No compatibility should be assumed. The firmware package must correspond to the terminal family, catalog number, hardware revision, and existing firmware requirements. The supplied data does not identify a specific compatible firmware revision.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the catalog number on the terminal nameplate before installation and configuration.\u003c\/li\u003e\n\u003cli\u003eConfirm the actual enclosure dimensions and mounting clearance against the applicable Allen-Bradley installation manual. The supplied source contains conflicting dimensional information and should not be used as the sole mechanical reference.\u003c\/li\u003e\n\u003cli\u003eProvide a 24 VDC nominal supply within the specified 18...30 VDC range.\u003c\/li\u003e\n\u003cli\u003eUse the required Class 2, SELV, or PELV power source.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables away from high-current power conductors, contactor wiring, and drive output cables where practical.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the plant grounding architecture and the applicable Allen-Bradley installation instructions.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between low-level communication wiring and switching or motor circuits to limit electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eDo not apply firmware intended for another PanelView terminal family without confirming hardware and firmware compatibility.\u003c\/li\u003e\n\u003cli\u003eConfirm the enclosure rating requirements for the actual installation environment before commissioning.\u003c\/li\u003e\n\u003cli\u003eProvide access for service of the field-replaceable real-time-clock battery.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet and RS-232 connections before energizing the terminal and confirm the communication configuration in the associated control system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43833450102874,"sku":"2711PC-T6C20D","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2711PC-T6C20D1.jpg?v=1786527929","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2711pc-t6c20d-panelview-plus-6-compact-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}