{"product_id":"allen-bradley-2713p-t7wd1-panelview-5310-operator-interface-terminal","title":"Allen-Bradley 2713P-T7WD1 PanelView 5310 Operator Interface Terminal","description":"\u003ch2\u003eAllen-Bradley 2713P-T7WD1 PanelView 5310 Operator Interface Terminal\u003c\/h2\u003e\n\u003cp\u003eConfigured for touchscreen visualization and Ethernet communication in ControlLogix 5570, ControlLogix 5580, and CompactLogix L1, L2, and L3 systems, the \u003cstrong\u003eAllen-Bradley 2713P-T7WD1\u003c\/strong\u003e (\u003cstrong\u003e2713P-T7WD1\u003c\/strong\u003e PanelView 5310 operator interface terminal) provides direct operator interaction with controller data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2713P-T7WD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView 5310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.75 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e7 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eTFT color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e800 x 480 WVGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e152 x 91 mm (6.0 x 3.6 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Input\u003c\/td\u003e\n\u003ctd\u003eTouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuation Rating\u003c\/td\u003e\n\u003ctd\u003e1 million presses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Force\u003c\/td\u003e\n\u003ctd\u003e100 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Half-Life\u003c\/td\u003e\n\u003ctd\u003e50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB RAM and 1 GB storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMI Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB RAM and storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eEthernet and USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5570, ControlLogix 5580, CompactLogix L1, L2, and L3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAspect Ratio\u003c\/td\u003e\n\u003ctd\u003e5:03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 2713P-T7WD1 provides one Ethernet communication interface for connection with supported Logix controller platforms.\u003cbr\u003eTwo USB ports provide additional physical communication interfaces specified for the PanelView 5310 terminal.\u003cbr\u003eController compatibility includes ControlLogix 5570, ControlLogix 5580, and CompactLogix L1, L2, and L3 platforms.\u003cbr\u003eTherefore, network configuration should match the controller communication architecture and assigned PanelView application settings.\u003cbr\u003eThe 800 x 480 WVGA display presents controller and application information through a color TFT interface.\u003cbr\u003eIts analog resistive touchscreen uses direct physical actuation and has a rated capacity of 1 million presses.\u003cbr\u003eThe external 18-30 VDC supply range defines the electrical input requirement for terminal operation.\u003cbr\u003eThe supplied data specifies 9 W power consumption at the 24 VDC input condition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage does the 2713P-T7WD1 require?\u003cbr\u003eA: The terminal accepts an external 18-30 VDC supply, with 24 VDC specified as the nominal input.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are provided on the terminal?\u003cbr\u003eA: The supplied specifications identify one Ethernet interface and two USB ports.\u003c\/p\u003e\n\u003cp\u003eQ: Which controller families are identified as compatible with this terminal?\u003cbr\u003eA: The listed platforms are ControlLogix 5570, ControlLogix 5580, and CompactLogix L1, L2, and L3.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the terminal according to the mechanical requirements of the selected enclosure and panel cutout.\u003cbr\u003eVerify that the installation provides adequate clearance for the rear connectors and connected cables.\u003cbr\u003eApply the specified 18-30 VDC supply through correctly rated field wiring and protection devices.\u003cbr\u003eConfirm polarity before energizing the DC input because reverse wiring can damage electronic equipment.\u003cbr\u003eRoute Ethernet communication wiring separately from high-voltage power conductors and high-noise switching circuits.\u003cbr\u003eAvoid excessive cable bending, mechanical tension, and unsupported connector loads during installation.\u003cbr\u003eTerminate protective grounding and shield connections according to the applicable panel grounding architecture.\u003cbr\u003eKeep communication cable shields continuous where required by the selected network installation standard.\u003cbr\u003eVerify Ethernet configuration, controller addressing, and application communication settings before placing the terminal into service.\u003cbr\u003eInspect USB and Ethernet connectors for secure engagement before applying operating power.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43874475769946,"sku":"2713P-T7WD1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/2713P-T7WD1.jpg?v=1787214578","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-2713p-t7wd1-panelview-5310-operator-interface-terminal","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}