{"product_id":"allen-bradley-500f-fod930-fiber-optic-link-module","title":"Allen-Bradley 500F-FOD930 Fiber Optic Link Module","description":"\u003ch2\u003eAllen-Bradley 500F-FOD930 Fiber Optic Link Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for electrical-to-optical signal conversion in industrial communication networks, the \u003cstrong\u003eAllen-Bradley 500F-FOD930\u003c\/strong\u003e (\u003cstrong\u003e500F-FOD930\u003c\/strong\u003e Fiber Optic Link Module) provides direct physical signal transmission and isolation functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e500F-FOD930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e20.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFiber Optic Link \/ Transceiver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eFiber optic interface, connector configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Medium\u003c\/td\u003e\n\u003ctd\u003eMultimode or single-mode optical fiber dependent on variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003eApproximately 850 nm or 1310 nm dependent on sub-variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transmission Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 100 Mbps or 1 Gbps dependent on protocol integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation for ground loop and EMI\/RFI reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ NEMA industrial control cabinet installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Function\u003c\/td\u003e\n\u003ctd\u003eFront-panel LED status indicators for power, signal, and fault conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Network Fiber Conversion Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 500F-FOD930 provides optical signal conversion for industrial communication links requiring electrical isolation and reduced electromagnetic interference exposure. The module supports fiber-based transmission paths where copper communication limitations affect distance, grounding, or noise performance.\u003c\/p\u003e\n\u003cp\u003eThe fiber interface separates communication conductors from field grounding systems through galvanic isolation. Additionally, optical transmission reduces susceptibility to EMI and RFI generated by industrial switching equipment, motor drives, and power distribution systems.\u003c\/p\u003e\n\u003cp\u003eThe module integrates with Allen-Bradley control architectures where fiber communication links require deterministic network behavior. Profinet and EtherNet\/IP deterministic networks are not generated by the module itself but depend on the connected automation platform configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 500F-FOD930 provide electrical isolation between connected communication segments?\u003cbr\u003eA: Yes. The module uses galvanic isolation through optical transmission to reduce ground loop effects and electrical interference coupling.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factors affect fiber communication performance?\u003cbr\u003eA: Fiber type, connector condition, bending radius, optical cleanliness, and correct grounding of associated cabinet equipment affect communication quality.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be installed directly on a PLC backplane?\u003cbr\u003eA: Installation depends on the specific Allen-Bradley system architecture and mounting requirements defined for the associated hardware platform.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 500F-FOD930 inside an industrial control cabinet with suitable mechanical protection and environmental control. Verify fiber connector compatibility before installation because optical interface types depend on the configured module variant.\u003c\/p\u003e\n\u003cp\u003eRoute fiber cables separately from high-voltage power conductors and high-frequency switching sources. Maintain proper fiber handling procedures, including protection against excessive bending, mechanical stress, and connector contamination.\u003c\/p\u003e\n\u003cp\u003eConnect cabinet grounding according to industrial electrical standards. Fiber communication provides signal isolation, but associated power supply and cabinet components still require correct protective grounding.\u003c\/p\u003e\n\u003cp\u003eVerify LED diagnostic indicators after power application to confirm operating status. Record optical link conditions and network parameters during commissioning for future maintenance reference.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43882251419738,"sku":"500F-FOD930","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/500F-FOD9302.jpg?v=1787284635","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-500f-fod930-fiber-optic-link-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}