{"id":43882650239066,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"5069-IB16","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 5069-IB16 Compact 5000 I\/O Digital Input Module","public_title":null,"options":["Default Title"],"price":12300,"weight":118,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 5069-IB16 Compact 5000 I/O Digital Input Module

Configured for 24 VDC field signal acquisition in CompactLogix 5380, ControlLogix 5580, and Compact 5000 EtherNet/IP adapter systems, the Allen-Bradley 5069-IB16 (5069-IB16 Digital Input Module) provides direct physical/electrical execution for ON/OFF signal detection through 16 sinking input channels.

Hardware Specifications

Parameter Specification
Model 5069-IB16
Brand Allen-Bradley / Rockwell Automation
Origin United States
Product Series Compact 5000 I/O
Product Type Digital Sinking Input Module
Input Channels 16 channels, 1 input group
Input Type Digital Sinking Input, 24 VDC Sink
Nominal Input Voltage 24 VDC
Operating Voltage 10 to 32 VDC
On-State Voltage 10 to 32 VDC
Off-State Voltage 0 to 5 VDC
On-State Current 2.0 to 5.5 mA
Off-State Current 1.5 mA maximum
MOD Power Voltage 18 to 32 VDC
MOD Power Current 75 mA maximum
SA Power Voltage 10 to 32 VDC
SA Power Current 4 A maximum pass-through
Module Isolation Voltage 250 V continuous, basic insulation
Input Filter Time OFF to ON and ON to OFF configurable: 0 ms, 0.1 ms, 0.2 ms, 0.5 ms, 1 ms, 2 ms, 5 ms, 10 ms, 20 ms
Removable Terminal Block 5069-RTB18-SPRING or 5069-RTB18-SCREW
Mounting Method DIN Rail, EN 50022 35 x 7.5 mm or 35 x 15 mm
Enclosure Type Open style
Operating Temp 0 deg C to 60 deg C
Weight 0.26 lbs
Power Consumption MOD power current 75 mA maximum

EtherNet/IP Backplane Communication and I/O Scaling

The 5069-IB16 operates within the Compact 5000 I/O architecture and exchanges input status data through high-speed backplane communication. The module supports I/O density scaling for CompactLogix and ControlLogix platforms by providing sixteen discrete input points in a compact DIN rail installation format.

The module firmware compatibility follows the Compact 5000 I/O platform requirements for controller recognition, configuration, and diagnostic functions. Therefore, controller firmware and module revision compatibility must be verified before system commissioning.

The sinking input design receives current from connected field devices and reports digital state changes to the controller system. Additionally, configurable input filter timing allows adjustment of signal response behavior according to field device switching characteristics.

Frequently Asked Questions

Q: What type of field signals can the 5069-IB16 process?
A: The module processes 24 VDC discrete ON/OFF signals from devices such as push buttons, limit switches, and photoelectric sensors through sinking input channels.

Q: Can the 5069-IB16 be installed without an enclosure?
A: The module uses an open-style enclosure rating and requires installation within an appropriate industrial cabinet or protected mounting environment.

Q: What terminal connection options are available for this module?
A: The module supports 5069-RTB18-SPRING and 5069-RTB18-SCREW removable terminal blocks for field wiring connections.

Field Installation Guidelines

Install the 5069-IB16 on an EN 50022 compatible DIN rail with adequate mechanical support and cabinet protection. Verify that the removable terminal block type matches the planned wiring method before field connection.

Separate input signal wiring from high-voltage power conductors and high-noise switching circuits to reduce electromagnetic interference. Use appropriate shield grounding practices when connected field devices require shielded cables.

Confirm that the 24 VDC field supply polarity, input common wiring, and sinking input configuration match the connected devices. Before startup, check controller recognition, module diagnostics, and field signal response through the automation software configuration environment.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products