{"product_id":"allen-bradley-5069-l306er-compactlogix-5380-controller","title":"Allen Bradley 5069-L306ER CompactLogix 5380 Controller","description":"\u003ch2\u003eAllen Bradley 5069-L306ER CompactLogix 5380 Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for industrial control execution in CompactLogix 5069 platforms, the \u003cstrong\u003eAllen Bradley 5069-L306ER\u003c\/strong\u003e (\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e CompactLogix 5380 Controller) provides direct physical\/electrical execution for controller processing, Ethernet communication, and local I\/O management.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5069-L306ER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompactLogix 5380 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCompactLogix 5069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum MOD Power Bus Current\u003c\/td\u003e\n\u003ctd\u003e450 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Inrush\u003c\/td\u003e\n\u003ctd\u003e850 mA for 125 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Passthrough Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9.55 A at 18 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum MOD Power Bus Current Rating\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e0.6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks Supported\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Modules Supported\u003c\/td\u003e\n\u003ctd\u003eUp to 8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Communication\u003c\/td\u003e\n\u003ctd\u003eDual 1 Gb Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Network Topologies\u003c\/td\u003e\n\u003ctd\u003eLinear, Star, and Device Level Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e29 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-style controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Network and Controller Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 5069-L306ER CompactLogix 5380 Controller integrates dual Gigabit Ethernet ports for EtherNet\/IP communication and supports selectable dual IP address operation. The controller architecture supports linear, star, and Device Level Ring network configurations for industrial communication layouts.\u003c\/p\u003e\n\u003cp\u003eThe CompactLogix 5069 platform provides scalable I\/O density through local module expansion, supporting up to 8 local I\/O modules. Controller processing includes 0.6 MB user memory capacity and support for 32 controller tasks.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility and controller configuration management are handled through the CompactLogix 5380 system environment. The controller supports DIN rail installation with open-style enclosure construction for control panel integration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5069-L306ER support hot-swapping of local I\/O modules during operation?\u003cbr\u003eA: The provided data does not specify hot-swap capability. Installation and replacement procedures should follow Allen Bradley CompactLogix 5380 system requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum MOD power bus current supported by the controller?\u003cbr\u003eA: The controller supports a maximum MOD power bus current of 450 mA, with a maximum MOD power bus current rating of 10 A for passthrough applications.\u003c\/p\u003e\n\u003cp\u003eQ: Which Ethernet network topologies are supported by the 5069-L306ER?\u003cbr\u003eA: The controller supports Linear, Star, and Device Level Ring network topologies through its Ethernet communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 5069-L306ER on a properly bonded DIN rail inside a suitable control enclosure. Verify MOD power bus wiring polarity before energizing the controller.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication cables separately from high-voltage power conductors and switching circuits to reduce electromagnetic interference. Use appropriate shield grounding methods according to the industrial network installation standard.\u003c\/p\u003e\n\u003cp\u003eConfirm the available MOD power bus capacity before connecting additional modules. Ensure local I\/O modules remain within the supported expansion quantity and system power limits.\u003c\/p\u003e\n\u003cp\u003eFollow Allen Bradley CompactLogix installation documentation for grounding, firmware compatibility checks, controller configuration, and network commissioning procedures.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43882670948442,"sku":"5069-L306ER","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/5069-L306ER2.jpg?v=1787291957","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-5069-l306er-compactlogix-5380-controller","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}