Allen Bradley 5094-IY8 FLEX 5000 Analog Input Module

Allen Bradley 5094-IY8 FLEX 5000 Analog Input Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 5094-IY8

  • Condition: In stock

  • Product Type: FLEX 5000 Analog Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 449g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43882995023962,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"5094-IY8","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen Bradley 5094-IY8 FLEX 5000 Analog Input Module","public_title":null,"options":["Default Title"],"price":12300,"weight":449,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen Bradley 5094-IY8 FLEX 5000 Analog Input Module

Configured for multi-signal analog acquisition in FLEX 5000 I/O systems, the Allen Bradley 5094-IY8 (5094-IY8 Analog Input Module) provides direct physical/electrical execution for voltage, current, RTD, and thermocouple measurement channels. The module supports 8 differential or single-ended inputs with Sigma-Delta conversion using multiplexed 24-bit ADC technology.

Hardware Specifications

Parameter Specification
Model 5094-IY8
Brand Allen Bradley
Module Type Analog 8-channel Current/Voltage/RTD/Thermocouple Input Module
Product Line FLEX 5000
Weight 0.99 lbs
Power Consumption 24 VDC supply required; module power consumption not specified
Input Channels 8 differential/single-ended analog inputs
Input Mode Differential and single-ended supported
Voltage Input Range +/-10 V, 0 to 10 V, 0 to 5 V
Current Input Range 0 to 20 mA, 4 to 20 mA
Resistive Input Range 1 to 500 ohm, 2 to 1000 ohm, 4 to 2000 ohm, 8 to 4000 ohm
RTD Input Types Platinum and nickel RTD sensors with supported alpha coefficients
Thermocouple Input Range +/-100 mV
Thermocouple Types B, C, D, E, J, K, L (TXK/XK), N, R, S, T
Voltage Input Impedance Greater than 1 Mohm
Current Input Impedance 90 ohm typical, 70 to 110 ohm range
RTD Input Impedance Greater than 1 Mohm
ADC Conversion Method Sigma-Delta, two 24-bit multiplexed ADC analog input architecture
Common Mode Voltage +/-10 V for differential mode
Terminal Base Required separately; not included with module

EtherNet/IP Deterministic I/O and FLEX 5000 Integration

The 5094-IY8 operates as a FLEX 5000 analog acquisition module within Allen Bradley distributed I/O architectures. The module receives field-side signals through a separate terminal base, allowing wiring termination independent from the removable electronic module.

The module supports Profinet / EtherNet-IP deterministic networks. The input architecture enables I/O density scaling by providing eight configurable channels in a compact FLEX 5000 form factor. Firmware flash compatibility follows the supported FLEX 5000 platform requirements for controller integration.

Frequently Asked Questions

Q: Does the 5094-IY8 include the field wiring terminal base?
A: No. The module is supplied without a terminal base. A compatible separate terminal base is required for field-side wiring connection.

Q: Can the input channels operate with different signal types?
A: The module supports voltage, current, RTD, and thermocouple measurement types. Channel configuration depends on the controller software and module settings.

Q: What conversion technology is used for analog measurement?
A: The module uses Sigma-Delta conversion with two multiplexed 24-bit ADC analog input circuits.

Field Installation Guidelines

Install the module on the specified FLEX 5000 terminal base before connecting field wiring. Verify that the terminal base configuration matches the application wiring requirements.

Use shielded instrumentation cable for low-level analog signals, including RTD and thermocouple circuits. Connect cable shields according to the control cabinet grounding design and avoid parallel routing with high-current power conductors.

Maintain separation between analog input wiring and switching circuits, motor cables, or high-frequency noise sources. Confirm sensor polarity, channel configuration, and signal range settings before commissioning.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products