{"product_id":"allen-bradley-5094-iy8-flex-5000-analog-input-module","title":"Allen Bradley 5094-IY8 FLEX 5000 Analog Input Module","description":"\u003ch2\u003eAllen Bradley 5094-IY8 FLEX 5000 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-signal analog acquisition in FLEX 5000 I\/O systems, the \u003cstrong\u003eAllen Bradley 5094-IY8\u003c\/strong\u003e (\u003cstrong\u003e5094-IY8\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution for voltage, current, RTD, and thermocouple measurement channels. The module supports 8 differential or single-ended inputs with Sigma-Delta conversion using multiplexed 24-bit ADC technology.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5094-IY8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog 8-channel Current\/Voltage\/RTD\/Thermocouple Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eFLEX 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC supply required; module power consumption not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 differential\/single-ended analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Mode\u003c\/td\u003e\n\u003ctd\u003eDifferential and single-ended supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0 to 10 V, 0 to 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Input Range\u003c\/td\u003e\n\u003ctd\u003e1 to 500 ohm, 2 to 1000 ohm, 4 to 2000 ohm, 8 to 4000 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Types\u003c\/td\u003e\n\u003ctd\u003ePlatinum and nickel RTD sensors with supported alpha coefficients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Input Range\u003c\/td\u003e\n\u003ctd\u003e+\/-100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, C, D, E, J, K, L (TXK\/XK), N, R, S, T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Impedance\u003c\/td\u003e\n\u003ctd\u003e90 ohm typical, 70 to 110 ohm range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Conversion Method\u003c\/td\u003e\n\u003ctd\u003eSigma-Delta, two 24-bit multiplexed ADC analog input architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V for differential mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Base\u003c\/td\u003e\n\u003ctd\u003eRequired separately; not included with module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic I\/O and FLEX 5000 Integration\u003c\/h3\u003e\n\u003cp\u003eThe 5094-IY8 operates as a FLEX 5000 analog acquisition module within Allen Bradley distributed I\/O architectures. The module receives field-side signals through a separate terminal base, allowing wiring termination independent from the removable electronic module.\u003c\/p\u003e\n\u003cp\u003eThe module supports Profinet \/ EtherNet-IP deterministic networks. The input architecture enables I\/O density scaling by providing eight configurable channels in a compact FLEX 5000 form factor. Firmware flash compatibility follows the supported FLEX 5000 platform requirements for controller integration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5094-IY8 include the field wiring terminal base?\u003cbr\u003eA: No. The module is supplied without a terminal base. A compatible separate terminal base is required for field-side wiring connection.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input channels operate with different signal types?\u003cbr\u003eA: The module supports voltage, current, RTD, and thermocouple measurement types. Channel configuration depends on the controller software and module settings.\u003c\/p\u003e\n\u003cp\u003eQ: What conversion technology is used for analog measurement?\u003cbr\u003eA: The module uses Sigma-Delta conversion with two multiplexed 24-bit ADC analog input circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module on the specified FLEX 5000 terminal base before connecting field wiring. Verify that the terminal base configuration matches the application wiring requirements.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cable for low-level analog signals, including RTD and thermocouple circuits. Connect cable shields according to the control cabinet grounding design and avoid parallel routing with high-current power conductors.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between analog input wiring and switching circuits, motor cables, or high-frequency noise sources. Confirm sensor polarity, channel configuration, and signal range settings before commissioning.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43882995023962,"sku":"5094-IY8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/5094-IY82.jpg?v=1787296368","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-5094-iy8-flex-5000-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}