{"product_id":"allen-bradley-6200p-ns3c1k-industrial-panel-pc","title":"Allen-Bradley 6200P-NS3C1K Industrial Panel PC","description":"\u003ch2\u003eAllen-Bradley 6200P-NS3C1K Industrial Panel PC\u003c\/h2\u003e\n\u003cp\u003eConfigured for industrial visualization and HMI monitoring, the \u003cstrong\u003eAllen-Bradley 6200P-NS3C1K\u003c\/strong\u003e (\u003cstrong\u003e6200P-NS3C1K\u003c\/strong\u003e Industrial Panel PC) provides direct computing, display, and communication functions. The unit supports 24 VDC operation, dual Ethernet connectivity, serial interfaces, USB ports, and Windows 10 IoT Enterprise.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6200P-NS3C1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Panel PC \/ Display Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.99 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e12.1 in to 15 in TFT color LCD, model dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eResistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Bezel Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eEmbedded industrial processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eIntegrated RAM and flash storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e128 GB SSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows 10 IoT Enterprise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003e64-bit operating system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003eDual-port Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-422 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eUSB ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Output\u003c\/td\u003e\n\u003ctd\u003eDual display output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAllen-Bradley Industrial Computing and Network Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe 6200P-NS3C1K provides dual-port Ethernet for industrial network communication and external system connectivity.\u003cbr\u003eIts serial interface supports RS-232, RS-422, and RS-485 physical communication standards for compatible field devices.\u003cbr\u003eUSB interfaces provide local connection points for supported peripheral equipment and service operations.\u003cbr\u003eThe 128 GB SSD provides local solid-state storage for the specified 64-bit Windows 10 IoT Enterprise platform.\u003cbr\u003eAdditionally, dual display output permits connection to compatible external display devices when supported by configuration.\u003cbr\u003eThe supplied data identifies a resistive touchscreen, suitable for direct operator interaction through the panel interface.\u003cbr\u003eThe front bezel is specified for NEMA \/ IP65 panel installation, subject to correct cabinet integration.\u003cbr\u003eNo pre-installed application software is specified, so application loading remains dependent on the final system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply is specified for the 6200P-NS3C1K?\u003c\/p\u003e\n\u003cp\u003eA: The supplied technical data specifies 24 VDC operation; power consumption is not provided.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are identified for this model?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data identifies dual Ethernet, RS-232 \/ RS-422 \/ RS-485 serial, and USB interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: Does the supplied data specify hot-swap capability?\u003c\/p\u003e\n\u003cp\u003eA: No hot-swap capability is specified, so installation and replacement should follow cabinet power isolation procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit in a compatible panel cutout while maintaining the specified front bezel sealing arrangement.\u003cbr\u003eVerify that the cabinet supply provides the specified 24 VDC input before energizing the equipment.\u003cbr\u003eRoute Ethernet and serial communication cables separately from high-voltage and high-current power conductors where practical.\u003cbr\u003eAvoid parallel routing beside motor feeders, contactor wiring, and unshielded switching conductors to reduce electromagnetic interference.\u003cbr\u003eTerminate cable shields according to the installed control system grounding architecture and applicable industrial wiring standards.\u003cbr\u003eUse the correct RS-232, RS-422, or RS-485 wiring topology for each connected device and interface.\u003cbr\u003eConfirm connector seating and cable retention before applying cabinet power or starting the operating system.\u003cbr\u003eMaintain sufficient enclosure clearance for thermal dissipation and prevent obstruction around accessible ventilation areas.\u003cbr\u003eVerify display, touchscreen, Ethernet, serial, USB, and external display functions after physical installation.\u003cbr\u003eBecause specific dimensions and power consumption are not supplied, confirm cabinet clearance and electrical loading from approved documentation before final installation.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43895677911130,"sku":"6200P-NS3C1K","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/6200P-NS3C1K2.jpg?v=1787551055","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-6200p-ns3c1k-industrial-panel-pc","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}