Description
Allen-Bradley 700-CPM Bulletin 700 Compact Control Relay
The Allen-Bradley 700-CPM, also cataloged as the 700-CPM Bulletin 700 Compact Control Relay, provides switching for AC and DC control circuits with configurable contact arrangements. The relay supports control coils, main contacts, auxiliary contacts, and optional plug-in surge suppression for PLC output protection.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 700-CPM |
| Brand | Allen-Bradley |
| Product Line | Bulletin 700 Compact Control Relays |
| Relay Type | Heavy-Duty Master Control Relay / Industrial Relay |
| Weight | 0.05 lb |
| Operating Temp | -25 deg C to +60 deg C |
| Power Consumption | AC inrush: approximately 30-45 VA; AC sealed: approximately 6-8 VA; DC holding: approximately 3-5 W |
| Rated Operational Voltage | Up to 600 VAC / 250 VDC |
| Rated Insulation Voltage | 690 VAC |
| Thermal Current Rating | 10 A to 16 A, depending on contact selection and enclosure |
| AC Switching Capacity | AC-15: 120 VAC / 6 A; 240 VAC / 3 A; 480 VAC / 1.5 A |
| DC Switching Capacity | DC-13: 24 VDC / 2.3 A; 110 VDC / 0.55 A; 220 VDC / 0.27 A |
| AC Coil Voltages | 24 VAC, 110/120 VAC, 220/240 VAC, 480 VAC, 50/60 Hz |
| DC Coil Voltages | 12 VDC, 24 VDC, 48 VDC, 110 VDC, 220 VDC |
| Contact Configuration | 4-pole base units; examples include 4 NO, 3 NO + 1 NC, and 2 NO + 2 NC |
| Auxiliary Contacts | Snap-on top-mount auxiliary blocks; expandable up to 8 poles |
| Mechanical Life | >= 15 million operations |
| Electrical Life | >= 1.5 million operations at rated load |
| Terminal Type | Screw terminals, IP20 finger-safe design |
| Mounting | 35 mm DIN rail according to EN 50022 or direct screw panel mounting |
| Surge Suppression | Optional RC networks, varistors, or diodes |
Industrial Control Relay Characteristics
The 700-CPM uses mechanical contact switching for discrete control circuits and supports both AC and DC coil configurations. Its fixed main contact arrangement can be supplemented with top-mounted auxiliary contact blocks when additional signaling points are required.
Optional plug-in surge suppression can be installed across the control coil. RC networks and varistors apply to AC coils, while diode suppression applies to compatible DC coil configurations.
The relay supports 35 mm DIN rail installation or direct panel mounting. Screw terminals provide the electrical connection between field wiring and the relay contact or coil circuits.
Contact selection determines the applicable thermal current and switching capacity. Therefore, the selected contact arrangement and load category must match the connected control circuit.
Frequently Asked Questions
Q: Can the 700-CPM be used directly with PLC outputs?
A: The relay coil can interface with a PLC output when the selected coil voltage and coil current requirements match the output circuit. Optional surge suppression can reduce coil-generated transients.
Q: Can the contact configuration be expanded after installation?
A: The supplied data specifies 4-pole base configurations with snap-on auxiliary blocks supporting expansion up to 8 poles.
Q: Is the relay suitable for both AC and DC switching?
A: Yes. The specified device supports AC and DC coil variants and provides separate AC-15 and DC-13 switching ratings according to the selected contact configuration.
Field Installation Guidelines
Mount the relay on a compatible 35 mm DIN rail or secure it directly to the panel using the specified mounting arrangement.
Verify the coil voltage before wiring. AC and DC coil variants require different supply characteristics and may require different suppression components.
Keep coil wiring separated from sensitive low-level signal wiring where practical. Route switching conductors to minimize unnecessary coupling into analog or communication circuits.
Install the selected surge suppressor directly at the relay coil terminals when suppression is required. Confirm that the suppressor type matches the coil circuit before energizing the device.
Terminate conductors securely at the screw terminals and maintain the enclosure clearances required by the panel design. Do not exceed the applicable contact voltage, current, or load-category ratings.
For grounded control systems, connect protective and functional grounding conductors according to the panel grounding scheme. Do not use signal shields as substitutes for protective grounding conductors.
After installation, verify contact continuity, coil energization, auxiliary contact operation, and suppression component installation before connecting the relay to the controlled circuit.
Features
We welcome bulk orders and have a minimum order quantity of just one unit.
Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.
For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.
We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.
We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.
Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.