{"product_id":"allen-bradley-700-cpm-bulletin-700-compact-control-relay","title":"Allen-Bradley 700-CPM Bulletin 700 Compact Control Relay","description":"\u003ch1\u003eAllen-Bradley 700-CPM Bulletin 700 Compact Control Relay\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 700-CPM\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e700-CPM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBulletin 700 Compact Control Relay, provides switching for AC and DC control circuits with configurable contact arrangements. The relay supports control coils, main contacts, auxiliary contacts, and optional plug-in surge suppression for PLC output protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e700-CPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eBulletin 700 Compact Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eHeavy-Duty Master Control Relay \/ Industrial Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eAC inrush: approximately 30-45 VA; AC sealed: approximately 6-8 VA; DC holding: approximately 3-5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 600 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e690 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Current Rating\u003c\/td\u003e\n\u003ctd\u003e10 A to 16 A, depending on contact selection and enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Switching Capacity\u003c\/td\u003e\n\u003ctd\u003eAC-15: 120 VAC \/ 6 A; 240 VAC \/ 3 A; 480 VAC \/ 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Switching Capacity\u003c\/td\u003e\n\u003ctd\u003eDC-13: 24 VDC \/ 2.3 A; 110 VDC \/ 0.55 A; 220 VDC \/ 0.27 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Coil Voltages\u003c\/td\u003e\n\u003ctd\u003e24 VAC, 110\/120 VAC, 220\/240 VAC, 480 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Coil Voltages\u003c\/td\u003e\n\u003ctd\u003e12 VDC, 24 VDC, 48 VDC, 110 VDC, 220 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003e4-pole base units; examples include 4 NO, 3 NO + 1 NC, and 2 NO + 2 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003eSnap-on top-mount auxiliary blocks; expandable up to 8 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 15 million operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 1.5 million operations at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, IP20 finger-safe design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail according to EN 50022 or direct screw panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Suppression\u003c\/td\u003e\n\u003ctd\u003eOptional RC networks, varistors, or diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Relay Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 700-CPM uses mechanical contact switching for discrete control circuits and supports both AC and DC coil configurations. Its fixed main contact arrangement can be supplemented with top-mounted auxiliary contact blocks when additional signaling points are required.\u003c\/p\u003e\n\u003cp\u003eOptional plug-in surge suppression can be installed across the control coil. RC networks and varistors apply to AC coils, while diode suppression applies to compatible DC coil configurations.\u003c\/p\u003e\n\u003cp\u003eThe relay supports 35 mm DIN rail installation or direct panel mounting. Screw terminals provide the electrical connection between field wiring and the relay contact or coil circuits.\u003c\/p\u003e\n\u003cp\u003eContact selection determines the applicable thermal current and switching capacity. Therefore, the selected contact arrangement and load category must match the connected control circuit.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 700-CPM be used directly with PLC outputs?\u003c\/p\u003e\n\u003cp\u003eA: The relay coil can interface with a PLC output when the selected coil voltage and coil current requirements match the output circuit. Optional surge suppression can reduce coil-generated transients.\u003c\/p\u003e\n\u003cp\u003eQ: Can the contact configuration be expanded after installation?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data specifies 4-pole base configurations with snap-on auxiliary blocks supporting expansion up to 8 poles.\u003c\/p\u003e\n\u003cp\u003eQ: Is the relay suitable for both AC and DC switching?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The specified device supports AC and DC coil variants and provides separate AC-15 and DC-13 switching ratings according to the selected contact configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the relay on a compatible 35 mm DIN rail or secure it directly to the panel using the specified mounting arrangement.\u003c\/p\u003e\n\u003cp\u003eVerify the coil voltage before wiring. AC and DC coil variants require different supply characteristics and may require different suppression components.\u003c\/p\u003e\n\u003cp\u003eKeep coil wiring separated from sensitive low-level signal wiring where practical. Route switching conductors to minimize unnecessary coupling into analog or communication circuits.\u003c\/p\u003e\n\u003cp\u003eInstall the selected surge suppressor directly at the relay coil terminals when suppression is required. Confirm that the suppressor type matches the coil circuit before energizing the device.\u003c\/p\u003e\n\u003cp\u003eTerminate conductors securely at the screw terminals and maintain the enclosure clearances required by the panel design. Do not exceed the applicable contact voltage, current, or load-category ratings.\u003c\/p\u003e\n\u003cp\u003eFor grounded control systems, connect protective and functional grounding conductors according to the panel grounding scheme. Do not use signal shields as substitutes for protective grounding conductors.\u003c\/p\u003e\n\u003cp\u003eAfter installation, verify contact continuity, coil energization, auxiliary contact operation, and suppression component installation before connecting the relay to the controlled circuit.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43895690756186,"sku":"700-CPM","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/700-CPM2.jpg?v=1787552931","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-700-cpm-bulletin-700-compact-control-relay","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}