{"id":43895747969114,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"700-HA32Z1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 700-HA32Z1 GP Tube Base Relay","public_title":null,"options":["Default Title"],"price":12300,"weight":91,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 700-HA32Z1 GP Tube Base Relay

Configured for relay-based circuit isolation and signal switching, the Allen-Bradley 700-HA32Z1 (700-HA GP Tube Base Relay) provides DPDT contact operation through a plug-in tube-base interface. The specified coil is 110 VDC, with two change-over contacts and a 10 A nominal contact rating.

Hardware Specifications

Parameter Specification
Model 700-HA32Z1
Brand Allen-Bradley
Manufacturer Rockwell Automation
Series 700-HA
Relay Type General Purpose Tube Base Relay
Contact Configuration DPDT, 2 Form C
Number of Change-Over Contacts 2
Coil Voltage 110 VDC
Contact Current Rating 10 A
Rated Thermal Current 10 A at 240 VAC
Contact Material AgNi
Electrical Connection Plug-in connection
Base Type Tube base, pin-style terminals
Protection Rating IP40
Width 32.8 mm
Height 54.1 mm
Depth 36.5 mm
Weight 0.20 lb
Operating Temp -40 deg C minimum specified
Power Consumption Not specified in supplied data
Electrical Life 100000 cycles minimum
Mechanical Life 50000000 operations, DC
Origin Italy
Actuation Type DC

Rockwell Automation identifies 700-HA32Z1 as a 700-HA General Purpose Tube Base Relay with 10 A contacts, DPDT configuration, and 110 VDC actuation.

PLC and Industrial Control Relay Characteristics

The 700-HA32Z1 uses two change-over contact sets for discrete circuit switching and control interposing. Its AgNi contact material supports the specified switching construction, while the plug-in connection permits installation through a compatible relay socket.

The 700-HA series uses tube-base relay construction with pin terminals, and compatible 8-pin sockets are documented for the series.

For control-panel integration, the 110 VDC coil circuit must remain electrically compatible with the relay control supply. The 10 A rating applies to the specified contact conditions and should not be treated as a universal load rating.

Frequently Asked Questions

Q: What coil voltage is specified for the 700-HA32Z1?

A: The official Rockwell Automation data specifies 110 VDC as the rated control supply voltage.

Q: Does the 700-HA32Z1 include an LED indicator?

A: The official product record lists LED indication as false for this exact catalog number.

Q: Is the relay supplied with its socket?

A: No. Rockwell Automation lists the 700-HA32Z1 as not complete with a socket, so socket selection must be handled separately.

Field Installation Guidelines

  1. Verify the relay catalog number and coil voltage before applying the control supply.
  2. Use a compatible tube-base socket and confirm the terminal arrangement against the applicable wiring documentation.
  3. Keep coil wiring physically separated from high-current switching conductors where practical.
  4. Route low-level control wiring away from contactor, motor, and variable-frequency-drive power cables.
  5. Terminate protective earth and panel grounding according to the enclosure and control-panel grounding scheme.
  6. Do not connect a 110 VDC coil to an AC control source or to a different DC voltage.
  7. Confirm contact load type, voltage, current, and switching duty before energizing the controlled circuit.
  8. Inspect the plug-in connection for correct seating and mechanical retention before commissioning.
  9. Provide appropriate external suppression where the switched load can generate inductive transients.
  10. Maintain the relay within the specified environmental conditions and prevent contamination that could compromise insulation or contact operation.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products