{"product_id":"allen-bradley-700-ha32z1-gp-tube-base-relay","title":"Allen-Bradley 700-HA32Z1 GP Tube Base Relay","description":"\u003ch2\u003eAllen-Bradley 700-HA32Z1 GP Tube Base Relay\u003c\/h2\u003e\n\u003cp\u003eConfigured for relay-based circuit isolation and signal switching, the \u003cstrong\u003eAllen-Bradley 700-HA32Z1\u003c\/strong\u003e (\u003cstrong\u003e700-HA\u003c\/strong\u003e GP Tube Base Relay) provides DPDT contact operation through a plug-in tube-base interface. The specified coil is 110 VDC, with two change-over contacts and a 10 A nominal contact rating.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e700-HA32Z1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e700-HA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Tube Base Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eDPDT, 2 Form C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Change-Over Contacts\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e110 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current Rating\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Thermal Current\u003c\/td\u003e\n\u003ctd\u003e10 A at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eAgNi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003ePlug-in connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Type\u003c\/td\u003e\n\u003ctd\u003eTube base, pin-style terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e54.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e36.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C minimum specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e100000 cycles minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e50000000 operations, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eItaly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuation Type\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eRockwell Automation identifies 700-HA32Z1 as a 700-HA General Purpose Tube Base Relay with 10 A contacts, DPDT configuration, and 110 VDC actuation.\u003c\/p\u003e\n\u003ch3\u003ePLC and Industrial Control Relay Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 700-HA32Z1 uses two change-over contact sets for discrete circuit switching and control interposing. Its AgNi contact material supports the specified switching construction, while the plug-in connection permits installation through a compatible relay socket.\u003c\/p\u003e\n\u003cp\u003eThe 700-HA series uses tube-base relay construction with pin terminals, and compatible 8-pin sockets are documented for the series.\u003c\/p\u003e\n\u003cp\u003eFor control-panel integration, the 110 VDC coil circuit must remain electrically compatible with the relay control supply. The 10 A rating applies to the specified contact conditions and should not be treated as a universal load rating.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What coil voltage is specified for the 700-HA32Z1?\u003c\/p\u003e\n\u003cp\u003eA: The official Rockwell Automation data specifies 110 VDC as the rated control supply voltage.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 700-HA32Z1 include an LED indicator?\u003c\/p\u003e\n\u003cp\u003eA: The official product record lists LED indication as false for this exact catalog number.\u003c\/p\u003e\n\u003cp\u003eQ: Is the relay supplied with its socket?\u003c\/p\u003e\n\u003cp\u003eA: No. Rockwell Automation lists the 700-HA32Z1 as not complete with a socket, so socket selection must be handled separately.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the relay catalog number and coil voltage before applying the control supply.\u003c\/li\u003e\n\u003cli\u003eUse a compatible tube-base socket and confirm the terminal arrangement against the applicable wiring documentation.\u003c\/li\u003e\n\u003cli\u003eKeep coil wiring physically separated from high-current switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eRoute low-level control wiring away from contactor, motor, and variable-frequency-drive power cables.\u003c\/li\u003e\n\u003cli\u003eTerminate protective earth and panel grounding according to the enclosure and control-panel grounding scheme.\u003c\/li\u003e\n\u003cli\u003eDo not connect a 110 VDC coil to an AC control source or to a different DC voltage.\u003c\/li\u003e\n\u003cli\u003eConfirm contact load type, voltage, current, and switching duty before energizing the controlled circuit.\u003c\/li\u003e\n\u003cli\u003eInspect the plug-in connection for correct seating and mechanical retention before commissioning.\u003c\/li\u003e\n\u003cli\u003eProvide appropriate external suppression where the switched load can generate inductive transients.\u003c\/li\u003e\n\u003cli\u003eMaintain the relay within the specified environmental conditions and prevent contamination that could compromise insulation or contact operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43895747969114,"sku":"700-HA32Z1","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/700-HA32Z12.jpg?v=1787554356","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-700-ha32z1-gp-tube-base-relay","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}