{"id":43895738859610,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"700DC-P400Z2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 700DC-P400Z2 Bulletin 700-P Heavy-Duty DC Control Relay","public_title":null,"options":["Default Title"],"price":12300,"weight":807,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 700DC-P400Z2 Bulletin 700-P Heavy-Duty DC Control Relay

Configured for switching DC control circuits, the Allen-Bradley 700DC-P400Z2 (700DC-P400 DC Control Relay) provides direct contact switching for DC-operated equipment and control circuits within Bulletin 700-P relay systems.

Hardware Specifications

Parameter Specification
Model 700DC-P400Z2
Base Model 700DC-P400
Brand Allen-Bradley / Rockwell Automation
Product Line Bulletin 700-P Heavy-Duty Industrial Relay
Product Type DC Control Relay
Contact Configuration 4 NO
Operating Coil Voltage 230 to 250 VDC
Contact Rating NEMA Heavy-Duty A600 / P600
Continuous Current Up to 10 A, according to provided data
AC Rating Class 20 A AC rating class
Enclosure Type Open type
Mounting Panel mount / DIN rail mount
Operating Temp -20 to +65 deg C
Weight 1.78 lb
Part Number 700DC-P400Z2

DC Coil and Industrial Control Characteristics

The relay uses a 230 to 250 VDC operating coil identified by the provided Z2 suffix designation. The four normally open contacts provide electrically actuated switching for external DC control circuits.

The open-type construction requires installation within an appropriate panel or protected control enclosure. Mounting provisions support panel and DIN rail installation according to the selected hardware arrangement.

As an Allen-Bradley Bulletin 700-P component, the device belongs to industrial control hardware rather than a PLC communication module. Therefore, Profinet, EtherNet/IP, firmware compatibility, and backplane bus parameters do not apply to this relay itself.

The contact interface should be evaluated against the connected load characteristics, including steady-state current, inrush current, and the electrical behavior of inductive loads.

Frequently Asked Questions

Q: What coil voltage is specified for the 700DC-P400Z2?

A: The provided data specifies a 230 to 250 VDC operating coil voltage.

Q: How many normally open contacts are provided?

A: The relay provides four normally open contacts for external control-circuit switching.

Q: Is a specific power consumption value provided?

A: No coil power-consumption value is included in the supplied technical data, so no numerical value is assigned.

Field Installation Guidelines

Install the relay on a mechanically secure panel or DIN rail location with adequate enclosure protection for the application.

Verify the control supply voltage before energizing the DC coil. Keep the coil wiring physically separated from unrelated low-level analog or communication wiring.

Route contact-load conductors according to the applicable panel wiring practices and maintain suitable separation from sensitive signal circuits.

For inductive loads, evaluate the load switching characteristics and provide suitable suppression where required by the circuit design.

Terminate protective and control wiring according to the applicable enclosure and electrical installation standards. Ensure all terminals remain mechanically secure after wiring.

Where shielded conductors are used for nearby instrumentation circuits, terminate shields according to the system grounding design and avoid creating unintended ground loops.

Inspect contact and coil wiring before commissioning, then verify correct normally open contact operation under the intended control sequence.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products