{"id":43903459754074,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"80025-551-01-R","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 80025-551-01-R Current Transformer Module Assembly","public_title":null,"options":["Default Title"],"price":12300,"weight":635,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 80025-551-01-R Current Transformer Module Assembly

The Allen-Bradley 80025-551-01-R, also cataloged as the 80025-551-01-R Current Transformer Module Assembly, operates as a dedicated hardware component for current measurement and electrical signal interface functions within industrial control systems.

Hardware Specifications

Parameter Specification
Model 80025-551-01-R
Brand Allen-Bradley / Rockwell Automation
Weight 1.40 lbs
Operating Temp 0 deg C to +60 deg C
Product Type Current Transformer Module Assembly
Current Transformer Ratio 1000/1 ratio
Voltage Rating 600 V
Frequency Range 50/400 Hz
Mounting Type Chassis mount / rack-mounted module slot
Cooling Method Convection cooling / integrated heat sink
Storage Temperature -40 deg C to +85 deg C
Relative Humidity 5% to 95% non-condensing
Compliance CE, UL Listed, RoHS compliant

EtherNet/IP and Industrial Control Hardware Integration

The Allen-Bradley 80025-551-01-R is designed as an industrial electrical interface component for current transformer signal processing. Integration within Allen-Bradley control architectures requires correct chassis placement, electrical isolation verification, and compatible system configuration.

The module assembly supports current transformer input applications with a 1000/1 ratio and 600 V electrical rating. Installation procedures must maintain conductor separation, signal integrity, and grounding practices according to industrial control panel standards.

Allen-Bradley hardware platforms typically require compatible firmware and configuration management when replacing or integrating control assemblies. Firmware flash compatibility and backplane communication parameters must be verified before commissioning.

Frequently Asked Questions

Q: What is the primary electrical function of the 80025-551-01-R assembly?
A: The assembly provides current transformer signal interfacing with a 1000/1 current ratio for industrial electrical monitoring applications.

Q: Does the available documentation specify hot-swap operation for this module assembly?
A: No hot-swap capability is specified. Installation should be performed with the control system power removed unless the system documentation confirms live insertion support.

Q: What installation precautions apply to current transformer wiring?
A: Current transformer circuits require correct terminal identification, secure connections, and proper shielding or grounding practices to prevent measurement errors and electrical interference.

Field Installation Guidelines

  • Verify the module identification and electrical ratings before installation into the control chassis.
  • Install the assembly in the designated rack or chassis position according to the system hardware manual.
  • Maintain separation between current transformer wiring and high-noise power conductors.
  • Apply proper cable routing practices to reduce electromagnetic interference.
  • Confirm grounding connections for shields and enclosure bonding according to site electrical standards.
  • Inspect terminal connections for mechanical tightness before system energization.
  • Validate current transformer polarity and ratio settings during commissioning procedures.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products