{"product_id":"allen-bradley-9324-rl0300enm-rslogix-500-standard-edition-programming-software","title":"Allen-Bradley 9324-RL0300ENM RSLogix 500 Standard Edition Programming Software","description":"\u003ch2\u003eAllen-Bradley 9324-RL0300ENM RSLogix 500 Standard Edition Programming Software\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 9324-RL0300ENM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e9324-RL0300ENM\u003c\/strong\u003e RSLogix 500 Standard Edition programming software, provides Ladder Logic programming and configuration functions for SLC 500 and MicroLogix controllers through supported RSLinx Classic communication drivers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9324-RL0300ENM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eRSLogix 500 Standard Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Type\u003c\/td\u003e\n\u003ctd\u003ePhysical CD\/DVD package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e32-bit Windows-based software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Controllers\u003c\/td\u003e\n\u003ctd\u003eSLC 5\/01 through SLC 5\/05; MicroLogix 1000, 1100, 1200, 1400, 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Language\u003c\/td\u003e\n\u003ctd\u003eLadder Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Software\u003c\/td\u003e\n\u003ctd\u003eRSLinx Classic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Drivers\u003c\/td\u003e\n\u003ctd\u003eSerial, Ethernet\/IP, DH485, DH+, ControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAllen-Bradley PLC Programming and Communication Functions\u003c\/h3\u003e\n\u003cp\u003eRSLogix 500 Standard Edition provides Ladder Logic programming functions for Allen-Bradley SLC 500 and MicroLogix controller families. The supported controller range includes SLC 5\/01 through SLC 5\/05 processors and MicroLogix 1000, 1100, 1200, 1400, and 1500 controllers.\u003c\/p\u003e\n\u003cp\u003eCommunication functions integrate with RSLinx Classic, which provides driver access for Serial, Ethernet\/IP, DH485, DH+, and ControlNet connections. Therefore, the programming environment depends on the applicable RSLinx Classic driver configuration for controller communication.\u003c\/p\u003e\n\u003cp\u003eThe 9324-RL0300ENM is supplied as physical media and specifies English as the software language. No firmware compatibility matrix or software revision number is provided in the supplied data.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which PLC families are supported by 9324-RL0300ENM?\u003c\/p\u003e\n\u003cp\u003eA: The software supports Allen-Bradley SLC 500 controllers from SLC 5\/01 through SLC 5\/05 and MicroLogix 1000, 1100, 1200, 1400, and 1500 controllers.\u003c\/p\u003e\n\u003cp\u003eQ: Which programming language is provided by RSLogix 500 Standard Edition?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specification identifies Ladder Logic diagrams as the programming language supported by this edition.\u003c\/p\u003e\n\u003cp\u003eQ: How does 9324-RL0300ENM communicate with supported controllers?\u003c\/p\u003e\n\u003cp\u003eA: RSLogix 500 integrates with RSLinx Classic for Serial, Ethernet\/IP, DH485, DH+, and ControlNet communication drivers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the software on a Windows system that satisfies the applicable RSLogix 500 and RSLinx Classic requirements. Confirm the installed communication driver before connecting to a controller.\u003c\/p\u003e\n\u003cp\u003eUse the appropriate physical communication interface and cable for the selected RSLinx Classic driver. Keep communication wiring separated from high-voltage and high-current conductors where practical.\u003c\/p\u003e\n\u003cp\u003eFor shielded communication cables, terminate shields according to the controller, network, and installation standard. Avoid creating unintended ground loops through multiple shield termination points.\u003c\/p\u003e\n\u003cp\u003eBefore online operations, verify the controller model, communication path, and selected processor configuration. Back up existing controller programs before downloading modified logic.\u003c\/p\u003e\n\u003cp\u003eDo not assume firmware compatibility from the catalog number alone. Verify the installed RSLogix 500 revision and controller firmware requirements against the applicable technical documentation before commissioning.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43920256172122,"sku":"9324-RL0300ENM","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/9324-RL0300ENM.jpg?v=1787823558","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-9324-rl0300enm-rslogix-500-standard-edition-programming-software","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}