{"product_id":"allen-bradley-e2107-70-00-1-10-ethernet-communication-module","title":"Allen-Bradley E2107\/70\/00\/1\/10 Ethernet Communication Module","description":"\u003ch3\u003eAllen-Bradley E2107\/70\/00\/1\/10 Ethernet Communication Module\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley E2107\/70\/00\/1\/10\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE2107\/70\/00\/1\/10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet communication module, operates as a dedicated hardware component for Ethernet\/IP data exchange within Series 2100 industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation defines E2107\/70\/00\/1\/10 as a fixed communication module within the Series 2100 platform. No configurable suffix matrix or optional hardware segmentation is identified in the provided material.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eE2107\/70\/00\/1\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSeries 2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eEthernet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e72 mm x 120 mm x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indication\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Function\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration Support\u003c\/td\u003e\n\u003ctd\u003ePLC, HMI, distributed automation devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Network Architecture\u003c\/h3\u003e\n\u003cp\u003eThe E2107\/70\/00\/1\/10 module exchanges cyclic and acyclic Ethernet\/IP traffic between PLC, HMI, and distributed automation devices through deterministic industrial Ethernet communication paths. Integrated Ethernet processing supports reduced communication latency during controller synchronization and remote device polling operations.\u003c\/p\u003e\n\u003cp\u003eThe module architecture permits DIN rail deployment inside compact industrial control cabinets while maintaining network accessibility through modular field integration methods. LED diagnostics provide physical-layer indication for link activity, communication state monitoring, and network troubleshooting procedures.\u003c\/p\u003e\n\u003cp\u003eCommunication handling is isolated from external serial conversion hardware by direct Ethernet\/IP implementation inside the module firmware environment. This arrangement reduces protocol translation overhead during controller-to-device messaging sequences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the E2107\/70\/00\/1\/10 require external protocol conversion hardware for Ethernet\/IP communication?\u003cbr\u003eA: The supplied specifications identify native Ethernet\/IP protocol support within the communication module. External protocol conversion hardware is not specified for standard Ethernet\/IP operation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be mounted directly inside standard DIN rail control cabinets?\u003cbr\u003eA: Yes. The module is specified for DIN rail installation within industrial automation enclosures.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are available on the hardware interface?\u003cbr\u003eA: The module includes LED indicators for network and module status monitoring during commissioning and fault diagnosis procedures.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43413322530906,"sku":"E2107\/70\/00\/1\/10","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/EK-2110-30-05-1-10_3b348a1f-e59a-488f-b4d8-dbaf30f10648.jpg?v=1779260516","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-e2107-70-00-1-10-ethernet-communication-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}