{"product_id":"allen-bradley-e2110-30-05-1-10-eddy-current-probe","title":"Allen-Bradley E2110\/30\/05\/1\/10 Eddy Current Probe","description":"\u003ch3\u003eAllen-Bradley E2110\/30\/05\/1\/10 Series 2100 Eddy Current Probe\u003c\/h3\u003e\n\u003cp\u003eConfigured for non-contact rotor displacement measurement in Series 2100 monitoring networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley E2110\/30\/05\/1\/10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eE2110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEddy Current Probe) provides direct electrical execution. The sensor assembly operates with eddy-current signal conversion for shaft vibration, axial position, and differential expansion monitoring. The associated PLC module variant supports discrete I\/O handling and ControlLogix backplane communication under 24 VDC operation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eModel Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2110\u003c\/td\u003e\n\u003ctd\u003eSeries 2100 base platform designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/30\u003c\/td\u003e\n\u003ctd\u003e30 mm probe tip configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/05\u003c\/td\u003e\n\u003ctd\u003eFactory-defined configuration code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/1\/10\u003c\/td\u003e\n\u003ctd\u003eAssembly and interface revision identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eE2110\/30\/05\/1\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Probes \/ PLC I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Size\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd\u003eRotor position, shaft vibration, differential expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (PLC module version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eConfigurable digital and analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit logic processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Throughput\u003c\/td\u003e\n\u003ctd\u003eUp to 125 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Integration\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5000 backplane compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e94 mm x 95.3 mm x 57.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eChassis-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe PLC module implementation exchanges process data through deterministic ControlLogix backplane communication paths with synchronized update handling between I\/O assemblies and controller memory. Network timing consistency depends on chassis loading, firmware revision alignment, and backplane slot allocation. For mixed analog and vibration-monitoring installations, shield termination and isolated routing reduce transient coupling between high-frequency probe circuits and Ethernet\/IP traffic conductors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the E2110\/30\/05\/1\/10 support hot-swapping during ControlLogix operation?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap behavior depends on the chassis configuration and controller firmware policy. Removal or insertion under power can generate I\/O connection faults and should follow controller inhibit procedures before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What grounding practice is recommended for the eddy current probe cable?\u003c\/strong\u003e\u003cbr\u003eA: The probe extension cable shield should terminate at a single-point instrumentation ground to reduce common-mode interference and circulating shield current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module operate adjacent to high-current motor drives?\u003c\/strong\u003e\u003cbr\u003eA: Physical separation between probe signal cabling and variable-frequency drive output conductors is recommended to minimize induced noise and transient coupling.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43413348614234,"sku":"E2110\/30\/05\/1\/10","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/EK-2110-30-05-1-10_3b348a1f-e59a-488f-b4d8-dbaf30f10648.jpg?v=1779260516","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-e2110-30-05-1-10-eddy-current-probe","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}