{"product_id":"allen-bradley-mvi46-pdps-profibus-dp-slave-communication-module","title":"Allen Bradley MVI46-PDPS PROFIBUS DP Slave Communication Module","description":"\u003cp\u003eConfigured for PROFIBUS DP slave communication in SLC 500 automation systems, the \u003cstrong\u003eAllen Bradley MVI46-PDPS\u003c\/strong\u003e (\u003cstrong\u003eMVI46-PDPS\u003c\/strong\u003e PROFIBUS DP Slave Communication Module) provides direct physical and data communication execution between the controller backplane and PROFIBUS networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI46-PDPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP Slave Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate Range\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Node Address\u003c\/td\u003e\n\u003ctd\u003e0 to 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Database\u003c\/td\u003e\n\u003ctd\u003e400 registers (200 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator Type\u003c\/td\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Position\u003c\/td\u003e\n\u003ctd\u003eSingle-slot chassis installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 g operational, 50 g non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e5 g from 10 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Networks and SLC 500 Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe MVI46-PDPS module operates as a PROFIBUS DP slave interface within the Allen Bradley SLC 500 platform. The module exchanges data through the controller backplane while maintaining PROFIBUS communication parameters configured by the application.\u003c\/p\u003e\n\u003cp\u003eThe module supports PROFIBUS node addressing from 0 to 125 and communication rates from 9.6 kbps to 12 Mbps. The internal database provides register storage for PROFIBUS data mapping between field devices and the SLC 500 processor.\u003c\/p\u003e\n\u003cp\u003eThe hardware design supports I\/O data exchange through a single-slot chassis installation. LED indicators provide local status information for communication monitoring and module diagnostics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What backplane load is required by the MVI46-PDPS module?\u003cbr\u003eA: The module requires 800 mA at 5 VDC supplied from the SLC 500 backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What PROFIBUS communication speeds are supported by this module?\u003cbr\u003eA: The MVI46-PDPS supports PROFIBUS DP communication rates from 9.6 kbps up to 12 Mbps.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MVI46-PDPS operate outside the specified ambient temperature range?\u003cbr\u003eA: The specified operating temperature range is 0 to 60 deg C. Installation outside this range requires additional environmental verification.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MVI46-PDPS module in an available single-slot position within the SLC 500 chassis while confirming backplane power capacity before operation.\u003c\/p\u003e\n\u003cp\u003eConnect PROFIBUS wiring using approved shielded cable practices. Terminate the network according to PROFIBUS installation requirements and maintain proper shield grounding to reduce communication interference.\u003c\/p\u003e\n\u003cp\u003eSeparate PROFIBUS communication cables from high-voltage power conductors, motor cables, and high-current switching circuits. Verify node addressing, baud rate configuration, and controller data mapping before commissioning.\u003c\/p\u003e\n\u003cp\u003eMaintain adequate ventilation around the chassis assembly and inspect LED status indicators during startup diagnostics.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43984572743770,"sku":"MVI46-PDPS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI46-PDPS2.jpg?v=1788257924","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-mvi46-pdps-profibus-dp-slave-communication-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}