{"product_id":"emerson-kl3106x1-ls1-i-s-thermocouple-input-charm-module","title":"Emerson KL3106X1-LS1 I.S. Thermocouple Input CHARM Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3106X1-LS1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Emerson is a single-channel analog input CHARM module engineered for thermocouple signals in DeltaV systems. Its intrinsically safe (I.S.) design ensures secure operation in hazardous environments, including Zone 2 and Class I Division 2 locations.\u003c\/p\u003e\n\u003cp\u003eFeaturing LS1 keyed terminals, this module prevents miswiring and simplifies installation. The compact CHARM format allows seamless integration into DeltaV racks while maintaining a minimal CHARM bus power draw. With broad environmental tolerance and robust resistance to shock, vibration, and airborne contaminants, it provides reliable temperature measurement in industrial conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3106X1-LS1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Type: Intrinsically Safe (I.S.) Analog Input CHARM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Type: Thermocouple input (supports multiple types)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Type: Intrinsically Safe (I.S.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCHARM Bus Power: +6.3 VDC at minimal consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Circuit Power: +24 VDC, ~60 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannels: Single-channel CHARM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Block Key Position: LS1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –40 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: 10 g, half-sine wave, 11 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirborne Contaminants: ISA-S71.04-1985 Class G3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance: No calibration required; no user-serviceable parts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous Atmosphere Ratings:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eII 3(1) G Ex ec [ia Ga] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eII 3G (1D) Ex ec [ia IIIC Da] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClass I, Division 2, Groups A–D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZone 2 AEx ec [ia Ga] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCertifications: ATEX, IECEx, FM, UKEX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation Note: Do not insert or remove while energized unless area is verified non-hazardous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-channel thermocouple input for accurate temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntrinsically safe design for hazardous area applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLS1 keyed terminal block ensures proper wiring and safe installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBroad environmental tolerance: –40 °C to +70 °C; resistant to shock, vibration, and Class G3 airborne contaminants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact CHARM module for seamless DeltaV system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement in hazardous areas using thermocouples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into DeltaV I\/O systems for process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for oil, gas, chemical, and other Zone 2 \/ Class I Div. 2 industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which thermocouple types are compatible with KL3106X1-LS1?\u003c\/strong\u003e\u003cbr\u003eA: Supports standard thermocouples including types J, K, T, E, R, S, B, and N depending on configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be installed in Zone 2 locations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is certified for Zone 2 and Class I Division 2 hazardous areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is calibration required before operation?\u003c\/strong\u003e\u003cbr\u003eA: No, the module is factory-calibrated and maintenance-free.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43064964415578,"sku":"KL3106X1-LS1","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/KL3103X1-LS11.jpg?v=1773804931","url":"https:\/\/www.plcmasters.com\/products\/emerson-kl3106x1-ls1-i-s-thermocouple-input-charm-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}