{"product_id":"epro-9100-00049-03-vibration-monitoring-module","title":"Epro 9100-00049-03 Vibration Monitoring Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9100-00049-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rack-based processing module developed for Emerson EPRO machine protection platforms. It evaluates input signals from eddy current measurement chains and converts them into actionable vibration and displacement data used for equipment protection and diagnostics.\u003c\/p\u003e\n\u003cp\u003eIt is typically deployed in MMS 3000 and MMS 6000 systems where continuous supervision of critical rotating assets is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Role in Measurement Chain\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWithin a complete monitoring loop, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9100-00049-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates downstream of signal conditioning hardware:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEddy current probe (PR642x series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal driver module (CON series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring and protection module (\u003cstrong\u003e9100-00049-03\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module processes incoming analog signals and applies configured logic to generate alarms, trips, and system outputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9100-00049-03\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: Signal evaluation and protection module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlatform compatibility: Emerson EPRO MMS 3000 \/ MMS 6000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: Plug-in rack format\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupported sensors: PR6422 \/ PR6423 \/ PR6424 \/ PR6426 probes (via drivers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput signal type: Analog voltage from CON-series drivers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement capabilities:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial displacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft position (gap measurement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency bandwidth: up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem accuracy: ≤ ±1% of full-scale (depending on calibration chain)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity reference: typically 8 mV\/µm (probe-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDynamic range: suitable for high-speed rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput and Control Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog outputs: configurable 0–20 mA or 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay outputs: independent alarm and shutdown contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital communication: integrated MMS rack backplane bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSetpoint configuration: adjustable thresholds for warning and trip levels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply: provided through MMS rack backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal isolation: galvanic separation between input, output, and internal bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSensor failure detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable integrity monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDriver signal verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal module health monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity tolerance: up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEMC performance: designed for high-noise industrial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: plug-in module for MMS rack systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront interface:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicators for status and alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest access points for signal verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration elements depending on hardware revision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine protection systems (steam and gas)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor and blower monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed motor and generator supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox vibration diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical process equipment protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous condition monitoring installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9100-00049-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a system-level module and relies on proper pairing with probes and driver electronics for accurate measurement. Calibration and scaling are determined by the complete signal chain rather than the module alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does this module connect directly to proximity probes?\u003c\/strong\u003e\u003cbr\u003eNo. It requires a CON-series signal driver between the probe and the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can it initiate machine shutdown?\u003c\/strong\u003e\u003cbr\u003eYes. It provides relay outputs for alarm and trip functions based on configured thresholds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is it compatible with all MMS systems?\u003c\/strong\u003e\u003cbr\u003eIt is designed specifically for MMS 3000 and MMS 6000 platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What kind of faults can it detect?\u003c\/strong\u003e\u003cbr\u003eIt can identify probe failure, cable disconnection, and abnormal signal conditions within the measurement chain.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43284395982938,"sku":"9100-00049-03","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/9100-00049-03_25f36c2f-8ba2-433a-b580-d5b7d6acadd8.jpg?v=1777367129","url":"https:\/\/www.plcmasters.com\/products\/epro-9100-00049-03-vibration-monitoring-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}